SECO-LARM Electromagnetic Locks
Installation
1. Fold the mounting template along the
dotted line to form a 90-degree angle.
Magnet
Drill 8mm ( / ") hole for cable access
5 16
Armature
1200-lb Electromagnetic Lock
E-941SA-1K2DPSQ
MT_E-941SA-1K2DPSQ_210115.cdr
3. Use a hammer to lightly
tap the two guide pins into
the guide pin holes on the
armature plate.
6. Depending on the type of door being protected, drill holes according to the diagrams below:
Hollow metal door
/
" (16mm)
/
5
5
8
16
Drill a
/
" hole (8mm) diameter hole
5
16
through the armature-plate side of the
door for the armature screw. Then drill a
/
" (16mm) diameter hole for the sexnut
5
8
screw on the opposite side of the door.
4
PLACE AGAINST HEADER
1 8
Drill 3.2mm ( / ") hole (2 places)
FOLD ON DOTTED LINE
PLACE AGAINST DOOR
Drill 8mm ( / ") hole for armature screw
5 16
Drill 6mm ( / ") hole for guide pins (12mm ( / ") in depth)
1 4
1 2
4. Place the template against
the door and frame. Mark
where the holes are to be
drilled.
" (8mm)
/
1
4
2. Close the door. Find a mounting location
on the door frame near the upper free-
moving corner of the door, or as close as
possible to the upper corner of the door
frame opposite the hinges.
Door frame
Door
Template
Reinforced door
" (6.8mm) for M8x1.25 thread
Drill a
/
" hole (6.8mm)
1
4
diameter and 1" (25mm)
deep hole, tap for
M8x1.25 thread.
Ideal
mounting
location
5. Drill holes in the frame and
the door as shown on the
template and in step #6
below. The smaller holes on
the door should not go all
the way through.
Door frame
Door
Solid-core door
/
" (12.7mm)
1
2
Drill a
/
" hole (8mm) diameter hole in
5
16
the door for the armature screw and drill
a
/
" (12.7mm) diameter and 1" (25mm)
1
2
deep hole from the opposite side for the
sexnut screw
SECO-LARM U.S.A., Inc.
Door frame
See step
#6 below
/
" (8mm)
5
16