TROUBLE REMINDER:
Choose
to initiate a daily 11:00AM reminder that there are uncleared trou-
YES
bles in the system. This reminder will appear on the screen and will sound a
piezo, if enabled. Choose
if no reminder is desired. Default: YES
NO
TROUBLE REMINDER DURATION:
4
24
between
and
HOURS
HOURS
ble reminders.
4
Choose
to initiate a trouble reminder every 4 hours until all troubles
HOURS
are clear. This option should be selected if the fire panel is connected to a wire-
less network via the FWSG/A. Choose
reminder every 24 hours until all troubles are clear. Default is 24 HOURS.
Press the Regional Settings softkey on the second Panel Settings screen to dis-
play the Regional Settings screen:
Press the soft key to scroll through the selections.

REGIONAL SETTINGS:

Choices are
,
CHICAGO
SINGAPORE
. The default is that there are no special regional settings.
DEFAULT
Press the SCS Settings softkey on the second Panel Settings screen to display
the SCS Settings screen:
Press to select mode
SCS MODE:
NOTE: For use with local SCS installations. Refer to the Smoke and
HVAC Control Station SCS Series Manual for additional information.
Press the Sounder Base Setup key on the third Panel Settings screen to display
the Sounder Base Setup screen.
Press to proceed to the Custom Tone Setup screen.
CUSTOM TONE SETUP:
The Pulse On time is the amount of time that the tone will
PULSE ON TIME:
be ON within a Period. Press this softkey to enter the amount of time in second
and fraction of a second increments.
A Period is the length of time designated for a pulse, including Pulse
PERIOD:
On time and Pulse Off time. The pulse off time is designated by the amount of
time left in a Period after the Pulse On time has expired. Press this softkey to
enter the amount of time in second and fraction of a second increments.
Press this softkey to enter the number of pulses that
NUMBER OF PULSES:
will occur before the Tone Off Period.
The Tone Off Period is the amount of time that the tone
TONE OFF PERIOD:
will be silent before running the pulse pattern again. Press this softkey to enter
the amount of time in seconds and fraction of a second increments.
Pulse Pulse
Period
Number of Pulses
Custom Tone Example
NFS2-3030 Listing Document — P/N LS10006-051NF-E:F2 5/19/2022
and
.
YES
NO
If Trouble Reminder is enabled: Toggle
to select the duration of time between trou-
24
to initiate a trouble
HOURS
,
,
,
AUSTRALIA
CHINA
CANADA
or mode
for SCS applications. Default: A
A
B
Tone Off Period
Repeat Tone Pattern
T R O U B L E R E M I N D E R : Y E S
T R O U B L E R E M I N D E R D U R A T I O N : 2 4 H O U R S
R E G I O N A L S E T T I N G : D E F A U L T
,
or
KOREA
S C S M O D E : A
C U S T O M T O N E S E T U P
P U L S E O N T I M E : 0 . 5
P E R I O D : 1 . 0
N U M B E R O F P U L S E S : 0 3
T O N E O F F P E R I O D : 1 . 5
R E M I N D E R M E N U
Reminder Menu Screen
R E G I O N A L S E T T I N G S
Regional Settings Screen
R E G I O N A L S E T T I N G S
SCS Settings Screen
S O U N D E R B A S E S E T U P
Sounder Base Setup Screen
C U S T O M T O N E S E T U P
Custom Tone Setup Screen
A C C E P T
B A C K
A C C E P T
B A C K
A C C E P T
B A C K
B A C K
A C C E P T
B A C K
35

Advertisement

Table of Contents
loading

Table of Contents