Download Print this page

Daikin RE18MV2S Service Manual page 11

Removal procedure

Advertisement

Si011193
Step
2. Remove the electrical
component ASSY.
Pull out the 2 terminals
1
[A1] [B1] from the fan
capacitor (C12R).
Pull out the terminal [5]
2
from the magnetic
contactor (K1M).
Release the fan motor
3
lead wire from the hook.
Pull out the terminal [1]
4
from the magnetic
contactor (K1M).
Pull out the 2 terminals
5
[A1] [B1] from the
compressor capacitor
(C11R).
6
Lift and remove the
electrical component
ASSY.
Removal Procedure
Procedure
Fan capacitor
Fan motor lead wire
Compressor capacitor
Electrical component ASSY
Removal of Electrical Components
Fan capacitor (C12R)
Magnetic contactor
Magnetic contactor (K1M)
(R15157)
Magnetic contactor (K1M)
Compressor capacitor
(C11R)
(R15174)
to compressor
(S terminal) :
yellow
Compressor lead wire
(R15175)
S(W) : yellow
C(U) : blue
R(V) : red
Points
to fan motor
(red)
B1 B2
A1 A2
to fan motor
(R15394)
(white)
A2
14
6
4
2
A1
13
5
3
1
to fan motor
(black)
(R15395)
A2
14
6
4
2
A1
13
5
3
1
to compressor (C terminal):
blue
(R17474)
B2
A2
B1
A1
to compressor
(R terminal) :
red
(R17473)
C(U)
R(V)
S(W)
(R15376)
9