  • Page 2 Service Manual Removal Procedure Outdoor Unit Cooling Only RN60HV1A RN60JV1...
  • Page 3: Table Of Contents

    Si011087 Table of Contents 1. Removal of Outer Panels ................2 2. Removal of Outdoor Fan / Fan Motor .............5 3. Removal of Electrical Component ASSY ..........7 4. Removal of Sound Blankets..............11 5. Removal of Capillary Tube..............12 6. Removal of Compressor ASSY (Pattern 1)...........13 7.
  • Page 4: Removal Of Outer Panels

    Removal of Outer Panels Si011087 1. Removal of Outer Panels Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1. Remove the top panel. Piping may be slightly Top panel different from the Remove the 8 screws...
  • Page 5 Si011087 Removal of Outer Panels Step Procedure Points Unfasten the hooks with a flat screwdriver and remove the suction Hook grille. (R5427) 2. Remove the front panel (2). Remove the screw and remove the front panel (2). Front panel (R12807) When reassembling, fit the 5 hooks.
  • Page 6 Removal of Outer Panels Si011087 Step Procedure Points 4. Remove the front panel (1). Remove the 6 screws and remove the front panel (1). Front panel (1) (R12810) (R5432) (R8322) Removal Procedure...
  • Page 7: Removal Of Outdoor Fan / Fan Motor

    Si011087 Removal of Outdoor Fan / Fan Motor 2. Removal of Outdoor Fan / Fan Motor Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Disconnect the relay Preparation connector for the fan Remove the front panel...
  • Page 8 Removal of Outdoor Fan / Fan Motor Si011087 Step Procedure Points Remove the nut and Nut size : M8 remove the outdoor fan. 13 mm (R12301) Lock washer (R15404) When reassembling, fit the D-cuts of the lock washer and the shaft of fan motor. D-cut (R12834) D-cut...
  • Page 9: Removal Of Electrical Component Assy

    Si011087 Removal of Electrical Component ASSY 3. Removal of Electrical Component ASSY Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1. Remove the side panel. Preparation Remove the top panel, front Remove the 9 screws...
  • Page 10 Removal of Electrical Component ASSY Si011087 Step Procedure Points 2. Remove the electrical Fan motor capacitor (C12R) component ASSY. Disconnect the 2 terminals from the fan motor capacitor (C12R). White (R16172) Detach the outdoor temperature sensor. Outdoor temperature sensor Remove the sensor fixing plate.
  • Page 11 Si011087 Removal of Electrical Component ASSY Step Procedure Points Remove the screw and remove the outdoor temperature thermostat. (R15486) Compressor capacitor Disconnect the (C11R) terminals from the capacitor (C11R). to compressor to compressor (R terminal) : red (S terminal) : yellow to magnetic contactor K1M(6): red (R17612)
  • Page 12 Removal of Electrical Component ASSY Si011087 Step Procedure Points Detach the clamp for the compressor lead wire (rear side). (R6749) Lift the electrical components ASSY to unfasten the 2 hooks and remove it. Electrical components ASSY (R15485) Removal Procedure...
  • Page 13: Removal Of Sound Blankets

    Si011087 Removal of Sound Blankets 4. Removal of Sound Blankets Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the sound Preparation blanket (top). Remove the electrical components ASSY according to the "Removal of Electrical Components...
  • Page 14: Removal Of Capillary Tube

    Removal of Capillary Tube Si011087 5. Removal of Capillary Tube Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Before working, make sure that the refrigerant Warning Brazed part gas is empty in the circuit.
  • Page 15: Removal Of Compressor Assy (Pattern 1)

    Si011087 Removal of Compressor ASSY (Pattern 1) 6. Removal of Compressor ASSY (Pattern 1) Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the terminal cover.
  • Page 16 Removal of Compressor ASSY (Pattern 1) Si011087 Step Procedure Points Remove the 4 nuts of the compressor. Warning Be careful not to get yourself burnt with the pipes and other parts that are heated by the gas brazing machine. Warning Before working, make If the refrigerant gas leaks sure that the refrigerant...
  • Page 17: Removal Of Compressor Assy (Pattern 2)

    Si011087 Removal of Compressor ASSY (Pattern 2) 7. Removal of Compressor ASSY (Pattern 2) Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the nut and remove the terminal Terminal cover cover.
  • Page 18 Removal of Compressor ASSY (Pattern 2) Si011087 Step Procedure Points Remove the gasket. Warning Be careful not to get yourself burnt with the pipes and other parts that are heated by the gas brazing machine. Warning If the refrigerant gas leaks during work, ventilate the room.
  • Page 19 Si011087 Removal of Compressor ASSY (Pattern 2) Step Procedure Points Note: Do not use a metal saw for cutting pipes by all means Suction pipe because the sawdust comes into the circuit. When withdrawing the pipes, be careful not to pinch them firmly with pliers.
  • Page 20 Revision History Month / Year Version Revised contents 01 / 2013 Si011087 First edition...
  • Page 21 Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.

This manual is also suitable for: