Daikin M Series Service And Troubleshooting page 49

13.4 seer2 single package dual fuel gas-electric heating & cooling units
Table of Contents

Advertisement

WIRING DIAGRAMS
L1
IIC
L1
LO
ODF
HI
LO
INDUCER
HI
L1
L1
P1
F
2
1
3
R
6
W1
8
W2
9
TO
MICRO
5
Y2
C
P2
1
Y1
4
5
3
6
G
TO
MICRO
LO HEAT
HI HEAT
COOL
R
C
W1
W1
R
C
DIAGNOSTIC
LED - RED
ON
OFF
1 FLASH
2 FLASHES
3 FLASHES
4 FLASHES
5 FLASHES
6 FLASHES
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
SUPPLY VOLTAGE
208-230/1/60
SEE NOTE 7
CH
CHS
SEE NOTE 8
T2
C
T1
R
C
COMP
S
H
RCCF C
DC
F
DF2
DF1
CM
HVDR
VM
SEE NOTE 3
EM
SEE NOTE 2
2
3
1
TR
ALS
LS
RS
PS
M
GV
7
HI
C
DR
6
4
2
3
1
HPS
RVC
2
DC
R
C-RV
O-RV
Y
CNT
R-DFT
DFT
R-PS1
LPS
DFT
C
1
T1
SEE NOTE 6
T2
EM C
2
T3
T5
T4
5
P9
SEE NOTE 5
2
W2
G
Y1
Y2
1
OTP
3
Y1
O
W2
G
++
THERMOSTAT
STATUS
NORMAL OPERATION
CHECK INPUT POWER
NO POWER OR
INTERNAL CONTROL
CHECK FUSE(S)
FAULT
REPLACE CONTROL
GAS PRESSURE
IGNITION FAILURE
FLAME SENSOR
CHECK PRESSURE SWITCH
PRESSURE SWITCH OPEN
CHECK TUBING
CHECK VENT MOTOR
PRESSURE SWITCH CLOSED
CHECK PRESSURE SWITCH
WITHOUT INDUCER ON
CHECK WIRING FOR SHORTS
CHECK MAIN LIMIT SWITCH
OPEN LIMIT SWITCH
CHECK AUXILIARY LIMIT SW.
CHECK ROLLOUT LIMIT SW.
CHECK GAS VALVE
FALSE FLAME DETECTED
CHECK FOR SHORTS IN
FLAME SENSOR WIRING
3 MIN COMP. SHORT
COMPR. SHORT CYCLE DELAY
CYCLE DELAY
L2
COMPONENT LEGEND
ALS
AUXILLARY LIMIT SWITCH
C
CONTACTOR
CH
CRANKCASE HEATER
CHS
CRANKCASE HEATER SWITCH
C
CM
CONDENSER MOTOR
COMP
COMPRESSOR
DC
DEFROST CONTROL BOARD
DFT
DEFROST THERMOSTAT
IIC
DR
DEFROST RELAY
EM
EVAPORATOR MOTOR
PARK
L2
F
FUSE
FS
FLAME SENSOR
L2
GND
EQUIPMENT GROUND
L2
GV
GAS VALVE
HPS
HIGH PRESSURE SWITCH
IIC
INTEGRATED IGNITION CONTROL
L2
IGN
IGNITOR
L2
LPS
LOW PRESSURE SWITCH
LS
LIMIT SWITCH
OTP
OUTDOOR THERMOSTAT PLUG
P1
9 PIN CONNECTOR PLUG
P2
6 PIN CONNECTOR PLUG
PS
PRESSURE SWITCH
RCCF
RUN CAPACITOR COMPRESSOR / FAN
RS
ROLLOUT SWITCH
RVC
REVERSING VALVE COIL
TR
TRANSFORMER
VM
VENT MOTOR
NOTES
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF
INSULATION AS ORIGINAL (AT LEAST 105°C). USE COPPER
CONDUCTOR ONLY.
2. FOR 208V TRANSFORMER OPERATION MOVE BLACK WIRE FROM
TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
3. FOR 208V VENT MOTOR OPERATION, REMOVE BLUE LEAD FROM
INDUCER LOW TERMINAL. MOVE BLACK LEAD FROM PARK TERMINAL
TO INDUCER LOW TERMINAL, AND PLACE BLUE LEAD ON PARK.
4. USE COPPER CONDUCTORS ONLY.
++
USE NEC CLASS 2 WIRE.
5. FOR OUTDOOR THERMOSTAT, REMOVE PLUG FROM HARNESS AND
CONNECT PLUG FROM OUTDOOR THERMOSTAT TO HARNESS.
6. TO CHANGE AIRFLOW MOVE YELLOW WIRE (COOLING / HEAT PUMP),
WHITE WIRE (LOW STAGE GAS), OR BROWN WIRE (HIGH-STAGE GAS)
O
W
TO SPEED TAP T1, T2, T3, T4, OR T5 AT EVAPORATOR MOTOR.
PS2
C
REFER TO UNIT AIRFLOW TABLES FOR TO DETERMINE THE
APPROPRIATE SPEED TAP FOR APPLICATION. UNITS SHIPPED WITH
YELLOW, WHITE, AND BROWN ON T4, T1, AND T2 RESPECTIVELY.
7. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY
EQUIPPED WHEN REQUIRED.
8. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR
COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION.
INTERNAL TO
INTEGRATED CONTROL
PLUG CONNECTION
SWITCH (PRESS.)
DIAGNOSTIC
CHECK
CHECK
LED - RED
-
-
7 FLASHES
8 FLASHES
GAS FLOW
GAS VALVE
9 FLASHES
DIAGNOSTIC
LED - AMBER
OFF
ON
1 FLASH
2 FLASHES
JUNCTION
EQUIPMENT GROUND
TERMINAL
FIELD GROUND
FIELD SPLICE
SWITCH (TEMP)
IGNITER
OVERCURRENT
PROT. DEVICE
STATUS
CHECK MAIN LIMIT SWITCH
LIMIT OPEN 5 TIMES IN
SAME CALL FOR HEAT
CHECK AUXILIARY LIMIT SW.
CHECK JUMPER BETWEEN
1 AND 4 ON 6-CIRCUIT
IDT/ODT OPEN
CHECK OPTIONAL
REFRIGERANT SWITCHES
CHECK REFRIGERANT
PSW/LOC OPEN
SWITCHES FOR LOSS OF
CHARGE OR HIGH HEAD
STATUS
NO FLAME PRESENT
NORMAL FLAME PRESENT
GAS PRESSURE
LOW FLAME SIGNAL
FLAME SENSOR
CHECK GAS VALVE
FALSE FLAME DETECTED
CHECK FOR SHORTS IN
FLAME SENSOR WIRING
(A/GPDM3[24-48]***41A*)
FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH
VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PK PINK
PU PURPLE
RD RED
WH WHITE
YL YELLOW
CHECK
CONNECTOR
PRESSURE
CHECK
-
-
GAS FLOW
GAS VALVE
0140G04501-B
49