Electrical Data; Wiring Diagrams - Carrier 62X Series Start-Up

Dedicated outdoor air unit
Table of Contents

Advertisement

ELECTRICAL DATA

Wiring Diagrams

See Fig. 99 and 100 for typical wiring information.
1.
1
L3
2
L2
3
L1
4
5
CS
6
7
OUTDOOR FAN MOTOR VFD
(OF1VFD)CONTROL TERMINAL STRIP
8
9
Y
10
11
Red
12
+12-30VDC
13
VRA1
VRA1
14
15
16
1 2 3
1 2 3
1 2 3
17
18
Red
+5VDC
19
BK
20
21
22
23
Circuit
Pressure Transducer
24
#2
25
26
27
28
29
30
31
SFR
SFR
32
9
9
33
34
See OEM Page For 0-10vdc Wiring Connec on
35
36
37
38
39
40
41
42
43
44
45
EFR
EFR
46
9
9
47
48
49
See OEM Page For 0-10vdc Wiring Connec on
50
51
52
53
54
55
56
57
58
59
WMR
WMR
60
9
9
61
62
See OEM Page For 0 - 10vdc Wiring Connec on
63
64
65
PDB
PDB
Y-12
O-12
BR-12
EGB
EGB
EGB
CURRENT SENSOR
CC1-AUX1
CC1-AUX1
Eaton DC1
Eaton DC1
R
OFVFD1
OFVFD1
CC2-AUX1
CC2-AUX1
R
24V
24V
1
1
Y
DI1
DI1
Y-12
2
2
DI2
DI2
O-12
3
3
AI2
AI2
BR-12
4
4
White
+0.5-4.5VDC
AI1
AI1
6
6
Red
+5VDC
0V
0V
7
7
White
+0.5-4.5VDC
Black
Y-12
Common
O-12
Circuit
BR-12
0-725PSIG
#1
0.5-4.5VDC
SF1VFD CONTROL
Eaton DC1
Eaton DC1
SFVFD1
SFVFD1
Y
24V
24V
1
1
Y
DI1
DI1
2
2
5
5
Y-14
O-14
BR-14
EF1VFD CONTROL
Eaton DC1
Eaton DC1
EFVFD1
EFVFD1
O
24V
24V
1
1
O
DI1
DI1
2
2
5
5
Y-14
O-14
BR-14
Y-14
O-14
BR-14
WMVFD CONTROL
F3
Eaton DC1
Eaton DC1
WMVFD
WMVFD
F2
PR
24V
24V
1
1
F1
PR
DI1
DI1
2
2
5
5
F10
F9
NOTE: SEE "T3" ON
SHEET #2 FOR WIRING
CONTINUATION
WIRING DIAGRAM #62X w/ERVWD | 62XM18TDJDGJGHBGZF | 460-3-60 | SHEET 1 OF 7 | 06/01/21 DWN
Fig. 99 — Typical Wiring Diagram
62X Electrical Data
Refer to the most current version of the dedicated outdoor air
builder for unit electrical data.
MSP-CC1
MSP-CC1
CC1
CC1
Y-12
L3
L3
T3
T3
L3
L3
O-12
L2
L2
T2
T2
L2
L2
BR-12
L1
L1
T1
T1
L1
L1
CC1-AUX1
CC1-AUX1
MSP-CC2
MSP-CC2
CC2
CC2
Y-12
L3
L3
T3
T3
L3
L3
O-12
L2
L2
T2
T2
L2
L2
BR-12
L1
L1
T1
T1
L1
L1
CC2-AUX1
CC2-AUX1
OFVFD1
OFVFD1
MSP-OFVFD1
MSP-OFVFD1
Y-12
L3
L3
W
W
Y-14
L3
L3
T3
T3
O-12
L2
L2
V
V
O-14
L2
L2
T2
T2
BR-12
L1
L1
U
U
BR-14
G-14
G-14
L1
L1
T1
T1
Y-14
O-14
BR-14
MSP-SF1
MSP-SF1
SFVFD1
SFVFD1
Y-14
L3
L3
W
W
L3
L3
T3
T3
O-14
L2
L2
V
V
L2
L2
T2
T2
BR-14
L1
L1
U
U
G-14
G-14
L1
L1
T1
T1
MSP-EF1
MSP-EF1
EFVFD1
EFVFD1
Y-14
L3
L3
W
W
L3
L3
T3
T3
O-14
L2
L2
V
V
L2
L2
T2
T2
BR-14
L1
L1
U
U
G-14
G-14
L1
L1
T1
T1
MSP-WM
MSP-WM
WMVFD
WMVFD
Y-14
L3
L3
W
W
L3
L3
T3
T3
O-14
L2
L2
V
V
L2
L2
T2
T2
BR-14
L1
L1
U
U
G-14
G-14
L1
L1
T1
T1
H2
H4
H3
Line
T1
Voltage
96 VA
50/60HZ
T3
CLASS 2
50/60HZ
24V
X1
XF
X2
67
Y-12
CC1-CS
CC1-CS
T3
T3
T3
T3
8
O-12
CM1
CM1
T2
T2
T2
T2
BR-12
T1
T1
T1
T1
CCH1
CCH1
G-14
G-14
Y-14
BR-14
Y-12
CC2-CS
CC2-CS
T3
T3
8
T3
T3
O-12
CM2
CM2
T2
T2
T2
T2
BR-12
CCH2
CCH2
T1
T1
T1
T1
G-14
G-14
Y-14
BR-14
MSP-OF1
MSP-OF1
Y-14
L3
L3
T3
T3
O-14
OFM1
OFM1
L2
L2
T2
T2
BR-14
L1
L1
T1
T1
MSP-OF2
MSP-OF2
Y-14
L3
L3
T3
T3
O-14
OFM2
OFM2
L2
L2
T2
T2
BR-14
L1
L1
T1
T1
Y-14
SF-CS
SF-CS
O-14
SFM1
SFM1
BR-14
Y-14
EF-CS
EF-CS
8
O-14
EFM1
EFM1
BR-14
Y-14
O-14
WM
WM
WM-CS
WM-CS
8
BR-14
5 (L3)
5 (L3)
4 (L2)
4 (L2)
PM
PM
3 (L1)
3 (L1)
H1
CONNECT TO TERMINAL H1 FOR UNITS RATED 460V.
CONNECT TO TERMINAL H2 FOR UNITS RATED 230V.
CONNECT TO TERMINAL H3 FOR UNITS RATED 208V.
SEE 575/600V TRANSFORMER FOR CORRECT WIRING
CONNECTIONS ON UNITS RATED 575V.
X3
G-14
SRF
LWF
CHK
.
G-14
G-14
G-14
G-14
G-14
G-14
G-14
G-14
G-14
G-14

Advertisement

Table of Contents
loading

Table of Contents