Troubleshooting - Procedure E; Verifying Thermistor Operation - Norcold DC0040 Service Manual

Compressor refrigerators
Hide thumbs Also See for DC0040:
Table of Contents

Advertisement

Troubleshooting - Procedure E

Verifying Thermistor Operation

To measure the resistance of the evaporator thermistor, com-
plete the following procedure.
1.
Turn the temperature control to the "Off" position.
2.
Disconnect the 3-pole connector. Refer to Figure 7.
3.
Measure the resistance across the two pins. Refer to
Figure 8.
4.
Check the evaporator thermistor by measuring the tem-
perature and resistance of the thermistor.
Refer to Table 1 for a listing of acceptable resistance
ranges.
NOTE: In general, 1.6K - 29KΩ = good thermistor.
∞Ω = defective thermistor. An open thermistor
will stop normal compressor operation. Replace
the defective thermistor.
Figure 7. Evaporator Thermistor Connection
(Inside Power Supply)
Thermistor Temperature
Refrigerator Service Manual
Evaporator Thermistor Resistance
(°F)
(°C)
0
-18
10
-12
20
-7
30
-1
40
4
50
10
60
16
70
21
80
27
90
32
Table 1. Evaporator Thermistor Resistance
DC0040(K), DC0051(K), DE0040, DE0051, DE0240T, DE0251T,
DC0740(X), DE0740(X), DC0751(X), DE0751(X) Models
Figure 8. Measure Resistance Across Pins
Resistance
Allowable
Resistance
Range
9.7 KΩ
8.7 - 10.7 KΩ
7.8 KΩ
7.0 - 8.6 KΩ
6.4 KΩ
5.7 - 7.0 KΩ
5.3 KΩ
4.8 - 5.7 KΩ
4.5 KΩ
4.0 - 4.9 KΩ
3.6 KΩ
3.2 - 4.0 KΩ
2.8 KΩ
2.5 - 3.1 KΩ
2.1 KΩ
1.9 - 2.3 KΩ
1.9 KΩ
1.7 - 2.0 KΩ
1.8 KΩ
1.6 - 1.9 KΩ