Troubleshooting- Procedure D; Measuring Compressor Amp Draw - Norcold DC0040 Service Manual

Compressor refrigerators
Hide thumbs Also See for DC0040:
Table of Contents

Advertisement

Troubleshooting- Procedure D

Measuring Compressor Amp Draw

Measure Amperage at
'A' on the Compressor
(See Figure 6)
Note: Measurements taken with 12.8V DC power supply.
Figure 6. Measuring Compressor Amp Draw
6
DC0040(K), DC0051(K), DE0040, DE0051, DE0240T, DE0251T,
DC0740(X), DE0740(X), DC0751(X), DE0751(X) Models
Compressor Amp Draw
40Watt < 1.6Amps
60Watt < 2.7Amps
40Watt = 1.6 – 2.0Amps
60Watt = 2.7 – 3.3Amps
40Watt > 2.0Amps
60Watt > 3.3Amps
A
Compressor
Change
Failure
Cooling Unit
Normal
Compressor
Change
Failure
Cooling Unit
Refrigerator Service Manual