2. Decrease Sensitivity—Press and release the
decrease shock sensor sensitivity by one step. The siren will
chirp 1-time for each step decreased in adjustment. When
the shock sensor adjustment reaches minimum sensitivity
(sensor is Off ) the siren will emit 1 short and then 1 long
chirp.
3. Testing Sensor—Use the heel of the palm of your hand to
strike the door pillar of the car after making an adjustment.
The siren will chirp once if the impact was great enough to
generate a full trigger. Pre-warn level is set automatically.
When desired setting is reached, sensor adjustment mode
can be exited.

exit shock sensor adjustment mode

The adjustment mode will be exited if:
No input from remote control for 15-seconds.
No input from sensitivity testing for 15-seconds.
The ignition is turned On.
The Valet button is pressed.
The siren will emit 1 long chirp and the LED will extinguish
which shock adjustment mode is exited.