Soft Dry Operation Mode - LG LPC483TAO Service Manual

Floor standing type air conditioner
Table of Contents

Advertisement

8. Soft Dry Operation Mode

• During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 2°C(3.6°F), the
compressor OFF temperature is the setting temperature minus 1°C(1.8°F).
• When the room temperature rises over the compressor ON temperature, the operation mode is switched to the
Cooling mode.
• When the room temperature falls between the compressor ON temperature and OFF temperature, the operation
mode is switched to the Soft Dry Operation.
• The operation diagram is shown below.
Intake Air Temp.
Setting Temp.
+2 C(3.6 F)
(Compressor ON)
Setting Temp.
-1 C(1.8 F)
(Compresso OFF)
Indoor Fan Speed
Compressor
9. Protection of the evaporator pipe from frosting
• Compressor and outdoor fan stop when indoor pipe temperature is below -2°C(28.4°F) and restart at the pipe
temperature is above 12°C(53.6°F).
10. Air Purifying Operation(AP-Z286RC0, AP-Z286R20, AP-Z488TC0)
Mode Selecting
Initial Starting of
Air purifying
Operation
When switched to
- Outdoor operating
Air purifying
- Main Operating +
operation
11. Child Lock function
This function is to operate Air conditioner only by Remocon.
The procedure is as the following
1st: Press the 2 buttons of the temperature control simultaneously, to raise-to lower on the Display Panel of the
product for more 3 seconds.
2nd: The buzzer sounds and then the window of Display Panel shows CL (CL) mark.
3rd: To release this function, the reverse again the operating procedure could be done.
During this function is operating, any buttons of Display Panel don't work. But it is possible to operate with
Remote controller.
Operation
Cooling
3 min.
Selecting
LOW
fan speed
ON
OFF
Operating Mode
- Outdoor not operating
- Fan operating + Air
purifying operating
Air purifying operating
Dry operation
maximum
10 min.
7 min.
LOW
LOW
ON
OFF
Fan Speed
- Low at the initial
- But could be
switched to Med. Hi
Selecting Speed of
Main Operating Mode
–20–
Cooling
operation
maximum
3 min.
10 min.
Selecting
LOW
LOW
fan speed
ON
OFF
ON
Outdoor
OFF
ON or OFF
depend on main
operating
condition.
LOW
OFF
OFF
Repress Air
purifying
Button or
ON/OFF
Button

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lp-c303r20Lp-c483ta0

Table of Contents