Read this owner's manual thoroughly before operating
the appliance and retain it for future reference.
TYPE : PORTABLE AIR CONDITIONER
MODEL : LP0818WNR
LP1018WNR
LP1218GXR
P/NO : COV34636801
Rev.0
Copyright © 2016 - 2017 LG Electronics Inc. All Rights Reserved.
www.lg.com

Advertisement

Table of Contents
loading

Summary of Contents for LG LP0818WNR

  • Page 1 Read this owner's manual thoroughly before operating the appliance and retain it for future reference. TYPE : PORTABLE AIR CONDITIONER MODEL : LP0818WNR LP1018WNR LP1218GXR www.lg.com P/NO : COV34636801 Rev.0 Copyright © 2016 - 2017 LG Electronics Inc. All Rights Reserved.
  • Page 2: Table Of Contents

    .........8 Control Panel and Remote ........10 Operation ..............12 ...........13 ......14 ......14 ......15 ....16 Installation in Vertical-Sliding Windows ....18 Installation in Horizontal-Sliding Windows ......20 Emptying the Water Collection Tank .............21 ..........21 ........22 ........23 LG Portable Air Conditioner Limited Warranty..25 Arbitration Notice…........…………..26...
  • Page 3: Important Safety Instructions

    SAFETY INSTRUCTIONS Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and follow all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or injure you and others. All safety messages will follow the safety alert symbol and either the word WARNING or CAUTION.
  • Page 4 • If water enters the product, turn off the power at the main circuit, then unplug the product and call for service. • If the product has been submerged, contact an LG Electronics Customer Information Center for instructions before resuming use.
  • Page 5 SAFETY INSTRUCTIONS CAUTION To reduce the risk of minor injury to persons, malfunction, or damage to the product or property when using this product, follow basic precautions, including the following: Operation • This appliance is not intended for use as a precision refrigeration system. Do not use it for special purposes such as maintaining pets, food, precision machinery, or art objects.
  • Page 6: Electrical Safety

    SAFETY INSTRUCTIONS ELECTRICAL SAFETY Lamp Do not use an adapter with this appliance.
  • Page 7 temperature, and using the bottom drain port.
  • Page 8: Before Using The Air Conditioner

    BEFORE USING THE AIR CONDITIONER Doing so they do place the appliance near...
  • Page 9 BEFORE USING THE AIR CONDITIONER Press and slide to remove the battery cover on the back of the remote. REMOTE STORAGE The air conditioner is designed with a convenient storage compartment for the remote. NOTE: When not in use, store the remote in the storage compartment with the buttons facing out.
  • Page 10: Control Panel And Remote

    Operation of functions is the same when using the remote or the control panel, unless otherwise stated. The remote and the control panel are not in sync. For best results when using the remote, remember to check that all desired settings are correct on the remote as well as on the control panel.
  • Page 11 In COOL mode, the buttons adjust the set temperature up to 86°F or down to 60°F, in one-degree increments. When the TIMER function is selected, use buttons to adjust the delay time from 0 to 24 hours, in one-hour increments. NOTE : In COOL mode, the thermostat in the air conditioner runs the compressor until the set temperature is reached, then cycles the...
  • Page 12: Operation

    HOW TO USE OPERATION MODES TIMER Use the Timer function to turn the air conditioner ON/OFF automatically. COOL Compressor runs and cools the room. Use the and FAN buttons to set the desired temperature and Setting the Air Conditioner to Turn ON fan speed.
  • Page 13 Mounting Flexible Vent Hose Diffuser Bracket...
  • Page 14 Assembling the Mounting Bracket, Diffuser, and Vent Hose 1. Use a pliers to extend the first four or five accordioned folds at both ends of the vent hose. 2. To attach the mounting bracket to one end of the vent hose, insert the extended folds on one side of the vent hose between the ridges inside one Unlock side of the mounting bracket.
  • Page 15 INSTALLATION INSTRUCTIONS WINDOW VENT PANEL AND EXTENSIONS The window installation kit allows you to install the air conditioner in most vertical-sliding windows 18” to 50” wide, or horizontal-sliding windows from 18” to 50” high. Window opening 1. Select the panels required based on the window opening, as shown above.
  • Page 16: Installation In Vertical-Sliding Windows

    INSTALLATION INSTRUCTIONS INSTALLATION IN VERTICAL-SLIDING WINDOWS NOTE : The window installation kit can be used with vertical-sliding windows between 18” and 50” wide. Cut the foam seal A (adhesive type) & C Insert the vent panel assembly, including (adhesive type-shorter) to the proper length, extension panels, if needed, into the opening.
  • Page 17 INSTALLATION INSTRUCTIONS INSTALLATION IN VERTICAL-SLIDING WINDOWS Insert the diffuser into the opening in the vent panel and slide it to lock it into place. Slot (2) Slide (1) Insert Align the tabs on the diffuser with the slots in the vent Insert the type C screw in the hole in the diffuser to panel.
  • Page 18: Installation In Horizontal-Sliding Windows

    INSTALLATION INSTRUCTIONS INSTALLATION IN HORIZONTAL-SLIDING WINDOWS NOTE : The window installation kit can be used with horizontal-sliding windows between 18” and 50” tall. Cut the foam seal A (adhesive type) & C Insert the vent panel assembly, including (adhesive type-shorter) to the proper length, extension panels, if needed, into the opening.
  • Page 19 INSTALLATION INSTRUCTIONS INSTALLATION IN HORIZONTAL-SLIDING WIDOWS Insert the diffuser into the opening in the vent panel and slide it to lock it into place. Slot (2) Slide (1) Insert Align the tabs on the diffuser with the slots in the vent Insert the type C screw in the hole in the diffuser to panel.
  • Page 20: Emptying The Water Collection Tank

    CARE AND CLEANING EMPTYING THE WATER COLLECTION TANK improves saves • This can be used when you need dehumidification in high humidity. • The upper drain port is not used in the Cool or Fan mode. • Remove the drain plug when using the Dry (dehumidifying) mode. •...
  • Page 21 CARE AND CLEANING CLEANING THE CASE CLEANING THE AIR FILTER filters each Use a vacuum cleaner to clean the filters. If the filters are heavily soiled, they can be washed in warm water using a mild detergent. filters filters.
  • Page 22 CARE AND CLEANING STORING THE AIR CONDITIONER extended period of time: Make sure the filters and drain cap are in place. Remove and clean the filters, allow them to dry completely, then reinstall them.
  • Page 23 TROUBLESHOOTING BEFORE CALLING FOR SERVICE Problem Possible causes Corrective Action Conditioner does not start. unplug the unit. room temperature Set the desired temperature to a level lower than the current temperature. Air Conditioner does not cool as it should. Set the desired temperature to a level lower than the current temperature.
  • Page 24 Error Possible causes Corrective Action Code Water tank is full. Drain water from the product through drain hole and reset settings. CH 01 Short/open circuit in Unplug the air conditioner and contact an CH 02 thermistor. authorized LG service center.
  • Page 26: Arbitration Notice

    The AAA Rules are available online at www.adr.org/consumer. Send a copy of your written demand for arbitration, as well as a copy of this provision, to the AAA in the manner described in the AAA Rules. You must also send a copy of your written demand to LG at LG Electronics, USA, Inc. Attn: Legal Department- Arbitration 1000 Sylvan Avenue Englewood Cliffs, NJ 07632.
  • Page 27 Memo...

This manual is also suitable for:

Lp1018wnrLp1218gxr

Table of Contents