5. Heating Mode Operation

The unit will operate according to the setting by the remote controller and the operation diagram is shown as
following.
Intake Air Temp.
Setting Temp. +1 C(1.8 F)
(Compressor OFF)
Setting Temp.
(Compressor ON)
Setting Temp. -1 C(1.8 F)
Indoor Fan Speed
Compressor
• A point: The indoor pipe temperature to be less then 35°C(95.0°F) & Discharge air Temperature to be less than 29°C(84.2°F).
The indoor fan operates for minimum 10sec. even if falls lower than 34°C(93.2°F).
During heating operation, the operating procedure of the indoor fan is as the following.
Discharge Air Temp.
Indoor Pipe Temp.
Step
Indoor fan speed
Selecting speed
Selecting speed
Hot
Start
minimum
10sec.
Selecting
OFF
fan speed
ON
Stop(VI)
39 C(102.2 F)
34 C(93.2 F)
28 C(82.4 F)
26 C(78.8 F)
Stop(I)
(Hot-Start Operating)
Off
Low
Low
Off
A
minimum
minimum
10sec.
10sec.
LOW
OFF
OFF
Low(V)
Selecting Fan Speed(IV)
(Hot-Start Release Point)
Heating Start
Low(II)
Pipe temp.
28 C(82.4°F)(Hot start operating)
28 C(82.4°F)
28 C(82.4°F)
28 C(82.4°F)
26 C(78.8°F)
26 C(78.8°F)
–18–
minimum
10sec.
Selecting
LOW
fan speed
ON
Selecting Fan Speed(III)
Air discharge temp.
< 39°C(102.2°F)
39°C(102.2°F)
> 34°C(93.2°F)
34°C(93.2°F)
A
OFF
OFF

Advertisement