Page 4
Reproduction in any manner whatsoever without the written permission of Dell Computer Corporation is strictly forbidden. Trademarks used in this text: Dell, Dell Precision, and the DELL logo are trademarks of Dell Computer Corporation. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products.
Page 5
NOTES: Dell recommends that only a technically knowledgeable person perform this procedure. Dell recommends that you read the entire procedure before you begin. You must also be familiar with removing the system cover and locating the RIMMs. Dell recommends that you print the contents of the system User’s Guide for referencing important information that may not be available during critical procedures.
Page 6
Click Go and follow the instructions on screen to create a diskette containing the BIOS update files. NOTE: For some Dell systems, you are given a choice to create a diskette con- taining the BIOS update files or to download a file you can use from the hard drive.
Page 7
Rambus in-line memory modules (RIMMs) in 64-, 128-, 256-, and 512-megabyte (MB) capacities. The RIMMs feature error checking and correction (ECC). Dell Precision 420 systems support a maximum of four RIMMs for up to 2 gigabytes (GB) of total memory.
Page 8
top of system Socket RIMMB_1 Socket RIMMA_2 Socket RIMMB_3 Socket RIMMA_4
When you add RIMMs, you must install them in matched pairs (pairs of identical capacity). If only one pair of RIMMs is installed, they must occupy sockets RIMMB_1 and RIMMA_2, and you must install continuity RIMMs (CRIMMs) in sockets RIMMB_3 and RIMMA_4.
Page 9
As the system boots, it detects the presence of the new RIMMs and automati- cally changes the system configuration information in system setup. NOTES: Adding or removing RIMMs causes the following message to be dis- played at the next system start-up: The amount of system memory has changed. support.dell.com System Memory Upgrade...
Page 10
If the memory total is still incorrect, contact Dell for technical support. See “Getting Help” in the User’s Guide. 12. Run the Dell Diagnostics to verify that the memory modules are operating properly. NOTE: For information on troubleshooting and running the Dell Diagnostics, see “Troubleshooting”...
Page 11
'
$(
'
%+
$
+
$
+
$
$
$
$(
Press the RIMM straight into the socket until the securing tabs snap into place around the ends of the RIMM. notches (2) securing clips (2)
support.dell.com System Memory Upgrade...
Page 12
&
+
$
$+ '
%+
$
+
$
$(
To remove a RIMM, press the securing clips outward simultaneously until the RIMM disengages from the socket (see Figure 1-3). It should pop out slightly. securing clips (2)
! System Memory Upgrade...
Page 13
Dell Precision ™ WorkStation 420 w w w . d e l l . c o m | s u p p o r t . d e l l . c o m...