Electrical Connection - Bosch Rexroth HEDE 10-3 Series Operating Instructions Manual

Electronic pressure sensor with switching and analog output
Table of Contents

Advertisement

22/48
7.1

Electrical connection

Voltage
!
Hazard caused by connection to supply outside the protective or
safety extra low voltage.
The sensor may exclusively be installed by a qualified electrical
worker.
Observe national and international regulations for the erection of
electrotechnical systems.
Observe voltage supply according to EN 50178, SELV, PELV.
With regard to cULus:
The device shall be supplied from an isolating transformer
having a secondary Listed fuse rated either
a) max 5 amps for voltages 0...20 Vrms (0...28.3 Vp) or
b) 100/Vp for voltages of 20...30 Vrms (28.3...42.4 Vp).
The device shall be connected only by using any Listed
(CYJV/7) or R/C (CYJV2/8) cord in respect of Condition
of Acceptability, having suitable ratings. (See ML File No.
E223220).
1. Disconnect the system from the power supply.
2. Connect the sensor as follows:
Bosch Rexroth AG, HEDE 10-3X, RE 30277-02-B/07.2016