9.2 Connecting the module

9.2.1 Electrical connection

Connector M12:
Pole: X-coded 8 poles M12 connector IEC 61076-2-109, According to IEEE 802.3

9.3 Handling

The use of a high pressure cleaner or chemicals is not permitted. For cleaning, it is recommended to use a rag lightly humid-
ified with water. Disassembly of the device by the end-customer is not permissible. Service and replacement of the product
may only be performed by authorized personnel. For protection of the device, the product should always be transported in
its original packaging and unwrapped only short before installation. Devices with visible damages (housing etc.) and devices
that might have exceeded the absolute maximum ratings (e.g. dropped down from a height of more than 1m onto a hard sur-
face) must not be used. Please pay special attention to the safety and warning notes in chapter 3 "Safety and warning notes".

9.4 Storage

Recommended storage conditions: Temperature: max. 25°C
Furthermore, the storage place must be well ventilated and the temperature changes must be slow in order to avoid water
condensation in the product. The device must be kept away from any potential source of heat and open flame. To avoid the
ingress of water or dust is a non-connected state a lid should be used to protect the connector during storage and/or transport.

10 IVAS Ecosystem

Hereinafter you can find a collection of scripts which should be used for demonstration purpose of the IVAS.

10.1 Hardware Setup

10.1.1 Required Equipment for testing and data logging

RaspberryPi 3B (linux based host) or higher / Linux workstation (preferred)*
External USB Storage (1,5 Mbit/s per device)
PoE Injector / PoE Switch
IVAS Sensor
*data rate handling is strongly depended of the performance of the client. To keep loss of data <1 % we recommend not to use more than 3 sensors with full
bandwidth together with a workstation as client in one ecosystem.