Abort Commands - Roland DXY-1300 Command Reference Manual

X-y plotter
Table of Contents

Advertisement

ESC.E
FORMAT
[ESC] .E
EXPLANATION
When this command is received, the DXY-1000 series outputs error codes about the RS-
232C interface, as shown in Table F5-6. At the same time, errors are cleared.
Error codes
An I/O error has not occurred.
0
While an output request is being executed, another command requesting output has been
10
received, but only the first command is valid.
11
A device control command error has occulted
A device control command parameter is unsuitable. (The parameter causing the error is set to
12
the default value.)
A parameter overflow has occurred
13
14
Too many parameters have been input, or the parameters were not terminated by
A framing error, parity error, or overrun error has occurred during reception of data.
15
16
The I/O buffer has overflowed. (In this case normal drawing operation is impossible.)
ESC.L
FORMAT
[ESC] .L
EXPLANATION
When this command is received, the DXY-1000 series outputs the current size of the I/O
buffer to the computer, usually outputting 1024 bytes.
Note:
Even with a 1M byte buffer, it will answer " 1024".
5.4.3

Abort Commands

ESC.J
FORMAT
[ESC].J
EXPLANATION
This command aborts the device control commands under execution.
Output error code
Error contents
Table 5-6
Output I/O buffer size
Abort device control
5 -2 2