Photoelectric Limit Switch Installation Instructions - Jackson Enodis AJ-54 Series Installation/Operation & Technical Manual

Rack conveyor dishmachine
Table of Contents

Advertisement

SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

PHOTOELECTRIC LIMIT SWITCH INSTALLATION INSTRUCTIONS

Installation Instructions:
1. Locate and drill a 3/4" diameter hole through the back of the
dishtable, 4" from the end and 3" above the surface of the table.
2. Using the switch mounting bracket template (a photocopy of it
may prove beneficial), locate and drill the 9/32" diameter hole on
either side of the 3/4" hole.
3. Mount the switch bracket to the outside of the dishtable using the
1/4"-20 hardware supplied. The cable entering the switch body
should be pointing upwards so that the switch sensitivity adjust-
ment screw is downwards for adjusting from the underside of the
table.
4. Wiring instructions:
a. White wire from the conveyor control panel to red/black wire
from proximity switch.
b. Door switch wire from the conveyor control panel to the black
wire from the proximity switch.
c. Black/white wire from the conveyor control panel to the red/white
wire from the proximity switch.
5. Adjust the sensitivity of the proximity switch by turning the
adjustment screw on the switch. The proper setting is reached
when the switch will sense an object approximately 12" from the
switch.
BRACKET MOUNTING TEMPLATE
AJ-54C Series Technical Manual 7610-002-30-91
Issued: 03-22-2006 Revised: N/A
30
Ø0.28
Ø0.75
3.00
SCALE 1:1
Unless noted, all dimensions
are in inches.

Advertisement

Table of Contents
loading