ELECTRICAL REQUIREMENTS (CONTINUED)/D226 STEAM BOOSTER PARAMETERS
AJ-90CE MODELS
VOLTS
PH
HZ
208
1
60
230
1
60
208
3
60
230
3
60
460
3
60
575
3
60
600
3
60
AJ-90CS MODELS
VOLTS
PH
HZ
208
1
60
230
1
60
208
3
60
230
3
60
460
3
60
575
3
60
600
3
60
NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided
on this page is for reference only and may be subject to
change without notice.
SECTION 1: SPECIFICATION INFORMATION
TYPICAL
TOTAL
ELECTRICAL
AMPS
CIRCUIT
115 A
150 AMP
106 A
150 AMP
68 A
90 AMP
63 A
80 AMP
32 A
40 AMP
25 A
35 AMP
26 A
35 AMP
TYPICAL
TOTAL
ELECTRICAL
AMPS
CIRCUIT
19 A
25 AMP
19 A
25 AMP
14 A
20 AMP
14 A
20 AMP
7 A
15 AMP
6 A
15 AMP
6 A
15 AMP
AJ-54C Series Technical Manual 7610-002-30-91
Issued: 03-22-2006 Revised: N/A
D226 STEAM BOOSTER
ELECTRICAL REQUIREMENTS:
VOLTAGE (V)
FREQUENCY (HZ)
PHASE
WATER REQUIREMENTS:
INCOMING WATER TEMPERATURE (MINIMUM)
FLOW PRESSURE (PSI)
STEAM REQUIREMENTS:
INCOMING STEAM PRESSURE (PSIG)
HEAT EXCHANGER SPECIFICATIONS:*
TUBESIDE WORKING PRESSURE (PSI)
SHELLSIDE WORKING PRESSURE (PSI)
TUBESIDE HYDROSTATIC TEST PRESSURE (PSI) 250
SHELLSIDE HYDROSTATIC TEST PRESSURE (PSI)
MAXIMUM OPERATING TEMPERATURE
MAXIMUM SHELLSIDE STEAM PRESSURE (PSI)
* - Indicates typical design criteria but is subject to change
without notice. For more information, contact you authorized
Jackson service representative.
WATER OUTLET SAFETY VALVE
SET PRESSURE (PSI):
STEAM RELIEF VALVE SET PRESSURE (PSI):
4
208-230
60
SINGLE
110°F
20±5
15-25
125
125
188
295°F
125
125