Install the DIMM.
7.
8.
Install the air baffle.
9.
Install the access panel (on page 22).
10.
Install the server into the rack.
11.
Connect each power cord to the server.
12.
Connect each power cord to the power source.
13.
Power up the server
Use the BIOS/Platform Configuration (RBSU) in the UEFI System Utilities to configure the memory mode.
For more information about LEDs and troubleshooting failed DIMMs, see "Systems Insight Display
LED combinations (on page 11)."
Installing an NVDIMM
CAUTION: Unlike traditional storage devices, NVDIMMs are fully integrated in with the
ProLiant server. Data loss can occur when system components, such as the processor or HPE
Smart Storage Battery fails. HPE Smart Storage battery is a critical component required to
perform the backup functionality of NVDIMM. It is important to take action when HPE Smart
Storage Battery related failures occur. Always follow best practices for ensuring data
protection.
1.
Power down the server (on page 21).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page 21).
o
Remove the server from the rack (on page 22).
4.
Remove the access panel (on page 22).
5.
Remove the air baffle.
6.
Locate any NVDIMM already installed in the server.
7.
Verify that all LEDs on any installed NVDIMMs are off. For more information on NVDIMM LEDs, see
"NVDIMM LEDs (on page 16)."
("Powering up the
server" on page 21).
Hardware options installation 52