Dometic DVF Holding Tank Vent Filter Installation And Operating Manual page 6

Ventilation filter
Table of Contents

Advertisement

Available languages

Available languages

Inserting the filter
4.2
Inserting the filter
➤ Remove the red stoppers from both connectors of the vent filter.
➤ Select a suitable adapter:
No. in
fig. 3,
Description
page 2
5a
Adapter for thread with 3/4" or 19mm ID hose
5b
Adapter for hose with 5/8" (16mm) – 3/4" (19mm) ID hose
5c
Adapter for hose with 1" (25mm) – 1-1/2" (38mm) ID hose
➤ Grease the O-ring on each connector of the vent filter using a liquid soap or sili-
cone grease.
➤ Be sure to push hose adapters completely over o-rings before threading the
retaining fastener to the filter.
➤ Screw the selected adapter together with the hose couplings (fig. 2 3, page 2)
on the vent filter.
➤ Insert the vent filter into the holder so that it latches into place.
For using thread adaptors only
➤ Check that there are seals (not included in delivery) in the connectors of the
hoses.
➤ Connect the vent hose from the tank (fig. 4 3, page 3) and the vent hose to the
hull vent pipes (fig. 4 1, page 3) with the vent filter (fig. 4 2, page 3).
➤ Tighten the connectors by hand.
➤ Tighten the connectors further by a 1/4 to 1/2 a turn using a tool.
For using threadless hose adaptors only
➤ Connect the vent hose from the tank (fig. 5 4, page 3) and the vent hose to the
hull vent pipes (fig. 5 1, page 3) with the vent filter (fig. 5 3, page 3).
➤ Secure the vent hoses on the adapters with hose clips (fig. 5 2, page 3).
6
DVF
EN

Advertisement

Table of Contents
loading

Table of Contents