FLOOR STANDING

General Data

CEA, CFA Cased Units
Table 1: Cased Floor Standing (CEA, CFA) Indoor Unit General Data.
Model No.
Cooling Mode Performance
Capacity (Btu/h)
Power Input
(W)
1
Heating Mode Performance
Capacity (Btu/h)
Power Input
(W)
1
Entering Mixed Air
Cooling Max. (°F WB)
Heating Min. (°F DB)
Unit Data
Refrigerant Type
2
Refrigerant Control
Sound Pressure
dB(A) (H/M/L)
3
Net Unit Weight (lbs.)
Shipping Weight (lbs.)
Communication Cable
(No. x AWG)
4
Fan
Type
Motor
Housing
Motor/Drive
Airflow Rate H/M/L (CFM)
High Mode (Factory Set)
External Static Pressure (in. wg)
High Mode (Factory Set)
Piping
Liquid Line (in., O.D.)
Vapor Line (in., O.D.)
Condensate Line (in., I.D.)
EEV: Electronic Expansion Valve
Power wiring is field supplied and must comply with the applicable local and national codes.
This unit comes with a dry nitrogen charge.
This data is rated 0 ft above sea level, with 25 ft of refrigerant line per indoor unit and a 0 ft level
difference between outdoor and indoor units. All capacities are net with a combination ratio between
95-105%.
Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and outdoor
ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
10 | FLOOR STANDING
ARNU073CEA4 ARNU093CEA4 ARNU123CEA4 ARNU153CEA4 ARNU183CFA4 ARNU243CFA4
7,500
9,600
85
85
8,500
10,900
85
85
76
76
59
59
R410A
R410A
EEV
EEV
35 / 33 / 31
36 / 34 / 32
59.5
59.5
68.3
68.3
2 x 18
2 x 18
Sirocco
Sirocco
2
2
3
3
300 / 265 / 229
335 / 300 / 265
0
0
1/4 Flare
1/4 Flare
1/2 Flare
1/2 Flare
1
1
Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
12,300
15,400
85
85
13,600
17,100
85
85
76
76
59
59
R410A
R410A
EEV
EEV
37 / 35 / 33
38 / 37 / 35
59.5
59.5
68.3
68.3
2 x 18
2 x 18
Sirocco
Sirocco
2
2
3
3
Brushless Digitally Controlled / Direct
371 / 335 / 300
406 / 353 / 335
0
0
1/4 Flare
1/4 Flare
1/2 Flare
1/2 Flare
1
1
Power Input is rated at high speed.
1
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy
2
R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608
of CAA.
Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
3
All communication cable to be minimum 18 AWG, 2-conductor, twisted, stranded, shielded and must
4
comply with applicable local and national codes. Ensure the communication cable is properly grounded
at the master outdoor unit only. Do not ground the ODU-IDU communication cable at any other point.
19,100
24,200
115
115
21,500
27,300
115
115
76
76
59
59
R410A
R410A
EEV
EEV
40 / 37 / 34
43 / 40 / 37
75.0
75.0
86.0
86.0
2 x 18
2 x 18
Sirocco
Sirocco
2
2
4
4
565 / 494 / 424
635 / 565 / 494
0
0
1/4 Flare
3/8 Flare
1/2 Flare
5/8 Flare
1
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents