The Trane EarthWise purge conversion package is
designed for application on low-pressure centrifugal
chillers, whether electrically or pneumatically controlled.
Note: The EarthWise purge is not designed to be applied
to air-cooled chillers.

Conversion Package Contents

Each EarthWise purge conversion "kit" includes the items
shown in Figures 3 through 5 as well as the items
described below that are field provided.

Field Provided Items

In addition to the factory provided components in the
conversion kit, the items listed below must be provided by
the installer:
Custom brackets (if needed) to mount purge on
condenser
Electrical conduit and inter-connection wiring (if
needed)
Miscellaneous electrical connectors
1/4" copper refrigerant tubing
3/8" copper refrigerant tubing
5/8" copper refrigerant tubing
Copper couplings, flare nuts, and tees
5/8" OD ball valve (required for units with heat
recovery or auxiliary condensers only)
Insulation for 5/8" vapor line
3/8" black nylon tubing for line to outside vent
Evaporator shut off valve for 1/4" regeneration line
Thermal grease
See optional purge valve kit (below) for other field
provided items
Insulation as required

Optional Purge Valve Kit

The following items are sold as a recommended option.
All of the parts listed below must be compatible with R-
123, R-11, and R-113.
Note: If the optional purge valve kit is not purchased,
these parts must be field provided.
1/4" NPS tee
1/4" C ball valve
1/4" coupling
3/8" NPS tee
3/8" C ball valve
3/8" coupling
PRGF-SVN001B-EN
7/8" ftg x 5/8" C bushing
7/8" ftg x 7/8" elbow
Coupling
5/8" C x 1.2" NPTE adapter
1/2" NPS elbow
5/8" ODS ball valve

Conversion Package Inspection

Before installing the new purge, compare the data on the
purge nameplate with the corresponding ordering and
shipping information to verify that the proper conversion
package was shipped.
If a thorough inspection of the conversion package reveals
damage or material shortages, file a claim with the carrier
immediately. Specify the extent and type of damage
found, and notify the appropriate Trane sales office.
Do not install a damaged purge unit without the Trane
sales representative's approval!
Note: The purge's sealed refrigeration system can be
easily bench tested through temporary connection
of 110 Vac power to the purge at the time of
inspection. See the unit wiring diagram for
connection points.
Table 1.
Description of contents in purge conversion kit
(some components for units ordered with
human interface only)
Number
Description
1
Bracket; Purge mounting
2
Screw; 0.25-20 x 1.00 thd rolling
3
Module; DynaView
4
Bracket; Human Interface mtg
5
Nut; 8-32 hex lock
6
Bushing; 0.75 ID x 1.00 OD snap
7
Cable; 4 stranded
Bracket; Human Interface unit
8
mtg
9
Screw; 0.25-20 x 0.50 thd rolling
Insulation; 3" x 5" temperature
10
well
11
Knobs; 0.31-18 with studs
Screw; 8-32 x 2.0 (attached to
12
DynaView)
Cable Connector; (attached to
13
DynaView)
14
Filter Drier
17
Screw; 0.25-20 x 0.50 thd rolling
19
Seal; 0.38 O-ring face
21
Sight Glass
22
O-ring (attached to filter drier)
23
Tube; 0.375 OD
General Information
Qty
Only in
Units with
Human
Interface
2
4
1
X
1
X
4
X
1
X
1
X
1
X
2
X
2
X
2
X
4
X
1
X
1
2
2
1
2
1
7

Advertisement

Table of Contents
loading

Table of Contents