Scalance X104-2 Tp Ports - Siemens SIMATIC NET SCALANCE X-100 Series Operating Instructions Manual

Industrial ethernet
Table of Contents

Advertisement

Product properties
3.4 SCALANCE X104-2
3.4.2

SCALANCE X104-2 TP ports

Connector pinout
On the SCALANCE X104-2, the TP ports are implemented as RJ-45 jacks with MDI-X
assignment (Medium Dependent Interface–Autocrossover) of a network component.
Figure 3-2
Table 3- 3
Pin number
Pin 8
Pin 7
Pin 6
Pin 5
Pin 4
Pin 3
Pin 2
Pin 1
NOTICE
TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45
TP port.
With the IE FC cables and IE FC RJ-45 plug 180, an overall cable length of a maximum of
100 m is permitted between two devices depending on the cable type.
14
RJ-45 jack
Pin assignment of the RJ-45 jack
Assignment
n. c.
n. c.
TD-
n. c.
n. c.
TD+
RD-
RD+