On-Site Configuration; Dip Switch Setting - Bosch Climate 5000 L Installation Instructions Manual

Large split air conditioner
Hide thumbs Also See for Climate 5000 L:
Table of Contents

Advertisement

4

On-site configuration

4.1

DIP switch setting

WARNING
Risk to life from electric shock!
Touching live electrical parts can cause an electric shock.
▶ Before working on electrical parts, disconnect all phases of the
power supply (fuse/circuit breaker) and lock the isolator switch to
prevent unintentional reconnection.
All DIP switches have been configured before delivery. The default
setting is highlighted bold.
▶ Only professional maintenance personnel should change these
settings.
▶ Improper DIP switch settings may cause condensation, noise, or
unexpected system malfunction.
Definition of DIP switch 0/1:
Definition 0
Definition 1
ENC1
Code
0
1
2
4
5
7
8
9
A
B
1) Default depending on the model
S1
S1 Setting
0 - F
0 - F
0 - F
0 - F
1) Default
Climate 5000 L • Climate 5000i U/L – 6721841492 (2022/03)
1)
Capacity setting
20
26
32 - 35
36 - 53
54 - 71
72 - 90
91 - 105
109 - 140
141 - 160
161 - 200
S2
Network address
1)
0 - 15
16 - 31
32 - 47
48 - 63
CL5000iU 4CC ...
DIP switch
Definition of DIP Switches
Fan OFF temperature when heating (anti-cold air function)
SW1
• [00]: 24°
• [01]: 8 °C
• [10]: 15 °C
• [11]: Reserved
Behaviour of the fan once the room target temperature has been
reached
SW2
• [0]: Fan off
• [1]: Fan on (anti-cold air function deactivated)
Auto restart
SW3
• [0]: Note setting
• [1]: Do no note setting
Set master and slave unit
SW5
• [00]: Master unit only, no slave unit
• [01]: Master unit (heating)
• [10]: Master unit (cooling)
• [11]: Slave unit
Temperature compensation (heating)
SW6
• [00]: 6 °C
• [01]: 2 °C
• [10]: 4 °C
• [11]: Reserved
1) Default highlighted in bold
CL5000iL 4C ...
DIP switch
Definition of DIP Switches
Fan OFF temperature when heating (anti-cold air function)
SW1
• [00]: 24 °C
• [01]: 15 °C
• [10]: 8 °C
• [11]: Reserved
Behaviour of the fan once the room target temperature has been
reached
SW2
• [0]: Fan off
• [1]: Fan on (anti-cold air function deactivated)
Auto restart
SW3
• [0]: Automatic restart on
• [1]: Automatic restart off
Set master and slave unit
SW5
• [00]: Master unit only, no slave unit
• [01]: Master unit (heating)
• [10]: Master unit (cooling)
• [11]: Slave unit
Temperature compensation (heating)
SW6
• [00]: 6 °C
• [01]: 2 °C
• [10]: 4 °C
• [11]: Reserved
Default cooling and heating or only cooling
SW7
• [0]: Cooling and heating
• [1]: Cooling only
1) Default highlighted in bold
On-site configuration
1)
1)
55