Trane BAYHTR1504BRKC Installer's Manual page 16

Supplementary electric heater
Table of Contents

Advertisement

Minimum Airflow CFM
Heater
BAYHTR1504BRK, BAYHTR1504LUG
BAYHTR1505BRK, BAYHTR1505LUG
BAYHTR1508BRK, BAYHTR1508LUG
BAYHTR1510BRK, BAYHTR1510LUG
BAYHTR1517BRK
BAYHTR3510LUG
BAYHTR3517LUG
BAYHTR1523BRK
BAYHTR1525BRK
Airflow Settings
Low
Med-Lo
Med-Hi
High
4
Page 16 of 20 10/16/2019
MOHS, PLANS EXAMINER
TEM6A0D60H51SB
TEM6A0D60H51SB Airflow Performance with Auxiliary Heat
Dip Switch Settings
Switch 7
ON
OFF
ON
OFF
REV #1
2405 E AINSWORTH AVE
INSTALL HVAC SYSTEM/PORT OF PASCO
Minimum Heater Airflow CFM
With Heat Pump
1150
1150
1150
1300
1150
1300
1380
1550
Nominal Airflow
Switch 8
ON
997
ON
1129
OFF
1350
OFF
1597
Without Heat Pump
975
975
975
1125
975
1125
1125
1345
See following tables for
heater application:
- Pressure Drop for
Electrical Heaters
- Minimum Heating
Airflow Matrix (on unit
nameplates)
TEM6A0D60-SUB-1E-EN
.
B19-2396
10/1/2019