Mechanical Specification Options - Trane BAYHTR1504BRKC Installer's Manual

Supplementary electric heater
Table of Contents

Advertisement

Mechanical Specification Options

G G e e n n e e r r a a l l
The Outdoor Units are fully charged from the factory
for up to 15 feet of piping. This unit is designed to
operate at outdoor ambient temperatures as high as
115°F . Cooling capacities are matched with a wide
selection of air handlers and furnace coils that are AHRI
certified. The unit is certified to UL 1995. Exterior is
designed for outdoor application.
C C a a s s i i n n g g
Unit casing is constructed of heavy gauge, galvanized
steel and painted with a weather-resistant powder paint
finish on all louvered panels and the fan top panel. The
corner panels are prepainted. All panels are subjected
to our 1,000 hour salt spray test . The base is made of a
CMBP-G30 weatherproof material to resist corrosion.
R R e e f f r r i i g g e e r r a a n n t t C C o o n n t t r r o o l l s s
Refrigeration system controls include condenser fan,
compressor contactor and high pressure switch. High
and low pressure controls are inherent to the
compressor. A factory supplied liquid line drier is
standard. Some models may require field installation.
American Standard optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand,
the leader in creating and sustaining safe, comfortable and energy efficient environments, American Standard offers a
broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more
information, visit www.americanstandardair.com.
American Standard has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice.
©2016 American Standard Heating & Air Conditioning
4A6H5060H-SUB-1A-EN 10 Jun 2016
Supersedes (New)
Page 12 of 20 10/16/2019
MOHS, PLANS EXAMINER
C C o o m m p p r r e e s s s s o o r r
The compressor features internal over temperature,
pressure protection and total dipped hermetic motor.
Other features include: Centrifugal oil pump and low
vibration and noise.
C C o o n n d d e e n n s s e e r r C C o o i i l l
The outdoor coil provides low airflow resistance and
efficient heat transfer. The coil is protected on all four
sides by louvered panels.
L L o o w w A A m m b b i i e e n n t t C C o o o o l l i i n n g g
As manufactured, this system has a cooling capacity to
55°F . The addition of an evaporator defrost control
permits operation to 40°F . The addition of an
evaporator defrost control with TXV permits low
ambient cooling to 30°F .
T T h h e e r r m m o o s s t t a a t t s s —Cooling only and heat/cooling (manual
and automatic change over). Sub-base to match
thermostat and locking thermostat cover.
E E v v a a p p o o r r a a t t o o r r D D e e f f r r o o s s t t C C o o n n t t r r o o l l — See Low Ambient
Cooling.
REV #1
2405 E AINSWORTH AVE
INSTALL HVAC SYSTEM/PORT OF PASCO
.
B19-2396
10/1/2019

Hide quick links:

Advertisement

Table of Contents
loading