Download Print this page

Advertisement

Quick Links

Installation
Before installation
Before installation, it is important
to read the information given on the
following pages as well as the
"Warning and Safety instructions" at
the beginning of this booklet.
Installation recommendations
- To achieve optimum vapour
extraction, the cooker hood must be
positioned centrally over the hob, not
to the side.
- The hob should be no wider than the
cooker hood, and if possible, it
should be narrower.
- The installation area must be easily
accessible. The cooker hood should
be easily accessible and easy to
dismantle in the event that service is
required. This should be taken into
consideration when planning the
position of cupboards, shelves,
ceilings or features in the vicinity of
the cooker hood.
Installation materials
1 vent connection
for exhaust ducting  150 mm.
12062340-01
1 non-return flap
for fitting into the exhaust socket on
the motor unit (not needed for
recirculation mode). Depending on the
model, the non-return flap may already
be fitted.
4 mounting plates
for installation in a 600 mm wide
cabinet
2 brackets
for installation in a 900 mm wide
cabinet (only for 900 mm wide
appliances)
2 spring clips
for installation in a 900 mm wide
cabinet (only for 900 mm wide
appliances)
1 spacer strip
for concealing the gap between the
rear of the appliance and the wall

Advertisement

loading

Summary of Contents for Miele DAS 4920

  • Page 1 *INSTALLATION* 12062340-01 Installation Before installation  Before installation, it is important to read the information given on the 1 non-return flap following pages as well as the for fitting into the exhaust socket on “Warning and Safety instructions” at the motor unit (not needed for the beginning of this booklet.
  • Page 2 *INSTALLATION* 12062340-01 Installation 4 screws, M4 x 8 mm DML 2000 installation kit for installing a hinged front panel to match kitchen furniture units (not supplied; available as an optional accessory) 4 (8)* screws, 4 x 15 mm Installation materials for recirculation mode You need the following optional 4 screws, 4 x 30 mm accessories for recirculation mode: 8 (12)* screws, 4 x 15 mm...
  • Page 3: Appliance Dimensions

    *INSTALLATION* 12062340-01 Installation Appliance dimensions Dia. 1: DAS 4620 in a 600 mm wide cabinet. The drawing is not to scale...
  • Page 4 *INSTALLATION* 12062340-01 Installation Dia. 2: DAS 4920 in a 900 mm wide cabinet. The drawing is not to scale See diagram 1 for side view...
  • Page 5 *INSTALLATION* 12062340-01 Installation Dia. 3: DAS 4920 in a 900 mm wide cabinet or in a 900 mm wide cabinet with side compartments. The drawing is not to scale See diagram 1 for side view Footnotes for diagrams 1 to 3: a The front section of the cabinet must be fitted with a base panel to secure the cooker hood.
  • Page 6: Safety Distance Between Hob And Cooker Hood (S)

    *INSTALLATION* 12062340-01 Installation Safety distance between hob and cooker hood (S) When planning the installation height of your cooker hood, the minimum safety distance between the top of a cooker or hob and the bottom of the cooker hood is as follows, unless a greater distance is specified by the manufacturer of your cooking appliance.
  • Page 7: Connection For Air Extraction

    *INSTALLATION* 12062340-01 Installation Connection for air extraction Any constriction of the air throughput will reduce extraction performance  If the cooker hood is used at the and increase operating noise. same time as a heating appliance that relies on oxygen from the same Flue room, there is a risk in certain circumstances of toxic fumes...
  • Page 8 If the exhaust is ducted through an outside wall, a Miele wall vent or roof vent (available as an optional accessory) is recommended. Both of these have a built-in non-return flap.
  • Page 9 *INSTALLATION* 12062340-01 Installation Silencer In recirculation mode, the silencer needs to be positioned between the exhaust vent and the exhaust grille . Check that there is sufficient space. To reduce noise levels even further, a silencer (optional accessory) can be installed in the exhaust ducting. In extraction mode, the silencer not only reduces noise from the fan outside the house, but also sounds originating...
  • Page 10 If the mains connection cable is damaged, it must only be replaced with a specific mains connection cable of the same type (available from the Miele Customer Service Department). For safety reasons, such replacement may only be carried out by a qualified specialist or the Miele Customer Service Department.

This manual is also suitable for: