2. PRODUCT SPECIFICATIONS
Items
Models
compressor
evaporator
condenser
Dryer
capillary tube(Dia×length)
Refrigerant
Model
theRMiStoR
(F-SenSoR)
502at
Model
theRMiStoR
(R-SenSoR)
502at
First Defrost cycle (concurrent defrost of F and R)
Defrost cycle(FRe)
Pause time
F Defrost-
Sensor
operating temperature
RS261MD **
Model
Mk172D-R2u/SM1
Starting type
oil charge
Freezer
Refrigerator
temperature Selection
bar 7 (-21
)
˚c
bar 4 (-20˚c)
bar 1 (-14˚c)
temperature Selection
bar 7 (0˚c)
bar 4 (2˚c)
bar 1 (8˚c)
6~20 hr(vary according to the conditions used)
Model
SPec
Rated
ac 125V / 6a
13
Specification
RS26DD **
D power
D power
Mk183c-l2u
R.S.c.R
FReol α -10
SPlit Fin tyPe
SPlit Fin tyPe
Forced and natural convection type
Molecular sieve xh-9
0.033 "×130 "
R134a
on(˚c)
oFF(˚c)
-21˚c
-25˚c
-18˚c
-22 ˚c
-12˚c
-16 ˚c
on(˚c)
oFF(˚c)
1˚c
-1˚c
3˚c
1˚c
9˚c
7˚c
6 hr ± 10 min
10 ± 2 min
theRMiStoR (502at)
5.0 k ohms at 25˚c (77˚F)
ac 250V / 3a
off : 60± 5˚c (104±9˚F)
on : 40± 5˚c (104±9˚F)
g power
Mk190g-l2u