Running the Power-On Self-Test (POST)

Table 1 POST Pass/Error
Messages
22
Running the Power-On Self-Test
(POST)
Run the POST to verify proper system installation.
Power on the library with the power switch on the back of the library.
The POST runs automatically at power on. The following message is
displayed:
PowerStor POST
Table 1 lists the tests that are run during POST along with the Operator
Control Panel (OCP) pass or fail messages associated with these tests.
POST Test -
Description
ROM EDC - Flash
ROM EDC
Micro RAM -
Microprocessor Local
RAM test
UART - QUART test
Other
Next the drive and the library are initialized. If the optional bar code
reader is present, the cartridge bar code labels are read. The OCP
buttons are not active until the Library Idle message is displayed.
Observe the display on the library OCP (see figure 18). The following
messages are displayed:
Library INIT
Library Idle
If all the POST tests are completed successfully, and the drive and
library are initialized, the library is ready for operation. If the tests did
not complete, run the POST again; if the tests are still not complete, the
library needs service.
ATL PowerStor L200 Series Library User's Guide
Pass Message
PowerStor POST 1
EDC
PowerStor POST 2
Micro RAM
PowerStor POST 3
UART
PowerStor POST 4
Other
Error Message
POST Error in
ROM EDC
POST Error in
Micro RAM
POST Error in
UART
POST Error in
Other