4.5

Easy Aimer installation

Note
When the Easy Aimer ball is loosened, the device is free to tilt to a maximum of 30°.
1. Holding the electronics enclosure firmly, loosen the Easy Aimer ball locking bolts and gently
reposition the enclosure.
2. Direct SITRANS LR460 so the horn antenna is pointed at an angle perpendicular to the
material surface, if possible. (As a guide, aim the beam at a point approximately 2/3 of the
way across the tank diameter.)
3. When the desired position is reached, retighten the 5 bolts to 15-23 N m (11 to 17 Lbf-ft).
SITRANS LR460
Compact Operating Instructions, 10/2021, A5E32007360-AB
Easy Aimer ball locking bolts
Top clamping plate (upper socket)
Bottom clamping plate (lower socket)
Customer gasket as required.
Recommended thickness 1.5 to 1.8 mm (0.06" to 0.07").
Customer mounting plate, as required ∅ 4" (102 mm) min. central opening