4.3
Nozzle location
• Locate antenna at least 1 meter away from side wall.
• Keep emission cone free of interference from ladders, pipes, I-beams or filling streams.
• Make allowance for beam spread to avoid interference with the emission cone.
Device orientation
• Align the antenna so that the radar cone is perpendicular to the surface of the monitored
material, if possible. See Easy Aimer installation (Page 19).
• To compensate for vessels with obstructions, see also Installation in vessel with
obstructions (Page 18).
SITRANS LR460
Compact Operating Instructions, 10/2021, A5E32007360-AB
Installing/mounting
4.3 Nozzle location
17