Figure2-9 Attaching the mounting brackets and chassis rails to an HPE 5944 48XGT 6QS28
(mounting brackets installed near the port side, rack mounting rail kit A or B)
Figure2-10 Attaching the mounting brackets and chassis rails to an HPE 5944 48XGT 6QS28
switch (mounting brackets installed near the power supply side, rack mounting rail kit A or
B)
Connecting the grounding cable to the chassis
IMPORTANT:
The primary and auxiliary grounding points are located on the left side panel of the chassis. The two
grounding points might be not reachable after the switch is mounted in the rack. Connect the
grounding cable to a grounding point before you mount the switch in the rack.
To connect the grounding cable to a grounding point:
1.
Unpack the grounding cable and grounding screws (applicable to both the primary and auxiliary
grounding points).
2.
Use the grounding screws to attach the two-hole grounding lug to the grounding point and then
fasten the screws, as shown in Figure2-11.
As a best practice, use a torque of 20 kgf-cm (1.96 Nm) to fasten the grounding screws.
2-11