Configuration - Omega iServer MicroServer EIS-2B User Manual

Serial to ethernet and internet
Table of Contents

Advertisement

4.3.4 Configuration

This section describes the "Configuration" page of the iServers's Web interface.
Click on
Configuration
When connecting your serial device to the iServer, the Serial Communications
parameters (baud rate, data bit, parity, and stop bit) must be the same on both, the
iServer and your serial device.
CONFIGURATION
http://192.168.1.200
Address
Baud Rate 9600
A
Flow Control none
B
TCP/UDP TCP
Connection Ctrl not used
C
Remote Access disable
Below are the definitions of terms used in the Configuration Page.
4.3.4.A Serial Communication
Baud Rate: The serial port speed can be set from 300 to 115,200 bits/s (default is 9600
bits/s.)
Data Bit: Options are 7 or 8 (default is 8 bits.)
Parity: Options are Odd, Even, and None (default is None.)
Stop Bits: Options are 1 and 2 bits (default is 1 bit.)
Flow Control: Options are Software Flow Control (Xon/Xoff), Hardware Flow Control
(CTS/RTS), and None (default is None).
, the following page should appear.
CONFIGURATION
Serial Communication
Data Bit 8 Bits
End Char (Hex) 00
Forward End Char enable
Serial Port Password disable
Terminal Server
Server Type slave
Remote Access (Tunneling)
Remote IP Address 0.0.0.0
Figure 4.12 Configuration
Parity none
Transciever RS-232
Modbus/TCP disable
1234abcd
Number of Connections 5
Connection Timeout 00100 msecs
Save Reset
Main Menu
23
Stop Bits 1 bit
Timeout 0
msecs
Local Port 02000
Device No. 1
Remote Port 02000

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iserver microserver eis-w

Table of Contents