Specification - Honeywell PRO-2200 Installation Manual

Hide thumbs Also See for PRO-2200:
Table of Contents

Advertisement

14

Specification

The Output board is for use in low voltage, class 2 circuits only.
Primary power:
12 VDC±10% 400mA
Relay contacts:
Relays 1 through 16 outputs, Form-C, 2A @ 28 VDC, resistive
Inputs:
Two unsupervised dedicated inputs
Communication:
RS-485:
Wire requirements:
Power
RS-485
Alarm inputs
Outputs
Mechanical:
Dimension
Weight
Environment:
Temperature
Humidity
Installation Guide
Range 9,600 to 38,400bps
1 twisted pair, 18AWG
24AWG, 4,000feet (1,200m) max.,
2 (120Ω, 23pF) twisted pair with shield (Belden 9842 or equiv.)
1 twisted pair per input, 30 ohms max.
As required for the load
5.5" (140mm) W x 9" (229mm) L x 1" (25mm) H
12 oz. (340g) nominal
0°C to +49°C, operating, -55°C to +85°C, storage
0% to 85% RHNC
PRO-2200 Output Module PRO22OUT