Download Print this page

Daikin BRC7EA618 Operation Manual page 10

Wireless remote controller kit

Advertisement

(2) Press OPERATION MODE SELECTOR
button several times and select "
(This operation is only available during
dry operation.)
ON OFF
2
ON/OFF
Press ON/OFF button
OPERATION lamp lights up or goes off and
the system starts or stops OPERATION.
NOTE
• Do not turn OFF power immediately after
the unit stops. Then, wait no less than
5 minutes.
Water is leaking or there is something else
wrong with the unit.
[EXPLANATION OF HEATING OPERA-
TION]
DEFROST OPERATION
• As the frost on the coil of an outdoor unit
increase, heating effect decreases and the
system goes into DEFROST OPERATION.
• The fan operation stops and the
DEFROST lamp of the indoor unit goes
on.
After 6 to 8 minutes (maximum 10 min-
utes) of DEFROST OPERATION, the sys-
tem returns to HEATING OPERATION.
Heating capacity & Outdoor air
temperature
• Heating capacity drops as outdoor air tem-
perature lowers. If feeling cold, use
another heater at the same time as this air
conditioner.
• Hot air is circulated to warm the room. It will
take some time from when the air conditioner
is first started until the entire room becomes
warm. The internal fan automatically turns at
low speed until the air conditioner reaches a
certain temperature on the inside. In this sit-
uation, all you can do is wait.
• If hot air accumulates on the ceiling and
feet are left feeling cold, it is recom-
mended to use a circulator. For details,
contact the place of purchase.
6
ADJUSTMENT
"
For programming TEMPERATURE, FAN
SPEED and AIR FLOW DIRECTION, follow
the procedure shown below.
DOWN
TEMPERATURE SETTING
UP
Press TEMPERATURE SETTING button
and program the setting temperature.
Each time this button is pressed,
setting temperature rises 1°C.
UP
Each time this button is pressed,
setting temperature lowers 1°C.
DOWN
In case of automatic operation
Each time this button is pressed,
setting temperature shifts to "H"
side.
UP
Each time this button is pressed,
setting temperature shifts to "L"
DOWN
side.
Setting
temperature
• The setting is impossible for fan operation.
NOTE
• The setting temperature range of the
remote controller is 16°C to 32°C.
FAN
FAN SPEED CONTROL
Press FAN SPEED CONTROL button.
High or Low fan speed can be selected.
The microchip may sometimes control the
fan speed in order to protect the unit.
AIR FLOW DIRECTION
SWING
ADJUST
Press the AIR FLOW DIRECTION
ADJUST button to select the air direc-
tion as shown below.
H
M
25
23
22
21
[°C]
L
19
English

Advertisement

loading

This manual is also suitable for:

Brc7e619Brc7e618Brc7ea619