2.
Trace the circuit for the cubed ice operation by closing the necessary switches. Refer to the
Wiring Diagram NOTES at the bottom of the page.
L1
NOTES:
1. Freezer door is open, ice dispenser selection in Cubed mode, and dispenser lock switch in Locked position.
2. The dispenser has a built-in inverter board which converts the 115 VAC to 115 VDC. The OR/BU wire is the
positive (+) side of the DC signal, and the PK/BK wire is the negative (–) side. The BR/WH and RD/WH wires
switch polarity, depending on the crushed/cubed switch position, (see the following table).
To Light Switch
BR/WH
Crushed
–
Cubed
+
7-2
RD/WH
+
–
N
ICE DISPENSER
MOTOR (SEE NOTE 2)