3.4 Flow Diagram
Number
1
0.01µm Pre-filter with Float Drain
2
Pressure Relief Valve
4.

INSTALLATION

4.1
Design and Use of the Activated Carbon Tower
The CLEARPOINT
®
separate oil aerosol and oil vapor contained in compressed air; any other use is improper. The manufacturer
is not responsible for any problems arising from the improper use of this machine. The end user, in any and
all cases, is responsible for any resulting damages.
Moreover, the correct use of this machine requires the verification of certain installation conditions, in
particular:
+ Pressure, temperature, flow rate and chemical composition of the incoming compressed air
+ Ambient temperatures
The carbon tower is supplied with the only operations left for the end user to: fill the tower with activated
carbon and connect to the plant with the instructions given in this manual.
CLEARPOINT V
9
Name
V activated carbon tower has been designed, manufactured and tested to be used only to
Series Activated Carbon Tower
®
Number
3
Vessel Pressure Gauge
4
1.0 µm Post-Filter with Manual Drain
(Rev. D)
Name

Advertisement