Heath Zenith 5610 Quick Start Manual

Heath Zenith 5610 Quick Start Manual

Motion sensor entryway light
Hide thumbs Also See for 5610:

Advertisement

Quick Links

Motion Sensor
Entryway Light
Models 5610/15
The Heath
/Zenith Motion Sensor Entryway Light turns
®
on up to 60 watts of incandescent light when motion
is detected and then, after a selectable time period,
automatically turns the light off. The built-in photocell
keeps the light off during daylight hours.
This package includes:
Sensor
globe
or
(5615)
Entryway Light
Mounting Nut and Stem
Requirements
• The Entryway Light requires 120-volts AC.
• If you want to use Manual Override, the light must be
wired through a switch.
• Some codes require installation by a qualified
electrician.
© 2015 HeathCo LLC
2 Screws
jar
(5610)
2 Wire
Connectors
Mounting Strap and
Grounding Wire
OPERATION
Mode:
On-Time
Test
5 Seconds
Auto
1, 5, or 10 Minutes
Manual
Until Dawn*
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
the circuitry to calibrate.
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the
1, 5, or 10 minute position.
MANUAL MODE
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Works:
Day Night
x
/
minutes for
1
2
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
1 Second
OFF then...
... back on.
Move ON-TIME Switch to
1, 5, or 10 minutes
Flip light switch off
for one second then
back on*
x
x
x

Advertisement

loading

Summary of Contents for Heath Zenith 5610

  • Page 1 Entryway Light * resets to Auto Mode at dawn. Note: When first turned on wait about 1 minutes for the circuitry to calibrate. Models 5610/15 TEST ON-TIME Put the ON-TIME switch on the bottom of the sensor in the TEST position.
  • Page 2 INSTALLATION 11. Caulk the back edge of the light and mounting surface with silicone weather sealant. For best performance, mount the fixture about 7 feet 12. Install a 60 Watt maximum light bulb into the lamp (2.1 m) above the ground. holder.
  • Page 3 3. Rotate the sensor base left Avoid aiming the control at: and right to aim the sensor. Adjust the sensor eye up • Objects that change temperature rapidly, such as heat- and down to obtain desired ing vents or air conditioners. These heat sources coverage range.
  • Page 4 TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE Light will not come Light comes on 1. Light switch is turned off. 1. Entryway Light may be sensing small animals or automobile traffic (re-aim 2. Light bulb is loose or burned for no apparent sensor).