Using The Input Power Cable - Intermec PB50 Installation Manual

Forklift power supply
Hide thumbs Also See for PB50:
Table of Contents

Advertisement

Chapter 1 — Introduction
One LED indicates main power is functioning (3-pin connector).
The secondary power LED indicates the heater power (2-pin
connector) is functioning.
Note: If the secondary LED is not lit, the input power
to the DC-DC converter is less than 9 to 10 Vx. It
will continue to provide 12 V output power to the
main power connector.
Power Supply (P/N 851-070-003) 6 to 60 V

Using the Input Power Cable

Note: Keep the cable as short as possible. Extra cable
picks up noise, adds power loss, and can snag on
equipment.
The input power cable may be shortened as needed. It
should not be extended on 12 V or lower systems. On
higher voltage systems, extensions should be kept to a
minimum and should be of equivalent or lower gauge
(larger diameter) wire. Keep the cable as short as
possible. Extra cable picks up noise, adds power loss,
and can snag on equipment.
The input cable from the power supply is approximately 2.74 m
(9.0 feet) long. One end has a 4-pin connector, the other has a
2-pin connector. By cutting off the unneeded connector, a single
cable can meet either 4 or 4.5 A current requirements. The cut
end is then terminated for connection to the forklift power
source. For detailed instructions on attaching the power cable, see
"Mounting the Power Supply" on page
4
PB50 and PW50 Forklift Power Supply Installation Guide
Output connector (secondary power)
Green LEDs (power output indicators)
Output connector (main power)
x
, 14 A
12.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pw50

Table of Contents