This command is used to enable or disable various sensors.
O[N,D,S]
Command
LTS
O
Enabled
ON
OD
Enabled
OS
Enabled
ON,D
OD,S
Enabled
ON,D,S
Default: ON
Label Taken Sensor:
When the label taken sensor is enabled, the communication to the printer will be
BUSY as long as the sensor detects a label in the outfeed slot.
DT Mode:
The ribbon end sensor is disabled and the density settings (see
are interpreted via a table that gives an optimized printout for direct thermal
printing.
TT Mode:
The ribbon end sensor (EasyCoder C4 thermal transfer model only) detects
refl ections from the trailing silvery part of the transfer ribbon. If the printer is set
to TT Mode, an error will occur if no refl ection is detected. The density settings
(see
D
command) are interpreted via a table that gives an optimized printout
for thermal transfer printing.
Reverse Gap Sensing:
This parameter reverses the operation of the label gap sensor so it interprets a blockage
of light as a gap between labels or similar. Before using the S parameter, make sure
to load the EasyCoder C4 printer with the appropriate type of media. By default, the
sensor will interpret blockage of light as a label or similar.