Industrial interface kit
Hide thumbs Also See for EasyCoder 501 SA:

Advertisement

EasyCoder 501/601 – Installation Instructions
INDUSTRIAL INTERFACE KIT, cont'd.
Step-by-Step Installation
Instructions, cont'd.
Rear Plate
Remove the existing cover plate.
Make sure that the CPU board is strapped and equipped for the
desired type of communication on "uart1:" (see the EasyCoder
501 or EasyCoder 601 Technical Manual). Once the interface
board has been fitted, it will be difficult to access the rear part of
the CPU board.
Fit the required straps on the Industrial Interface Board as
described on page 5.
Connect the cable from the interface board to connector P-4 at
the bottom rear corner of the CPU board. Be careful so the
interface board and the CPU board do not come in contact with
each other, which possibly may cause damage or short-circuiting.
Fit the interface board assembly to the printer's rear plate from
the inside as illustrated below using the same screws that held the
removed cover plate.
Screw
Female DB25
Connector
"uart3:"
Female DB15
I/O Connector
Screw
Industrial
Interface Board
Connect to P-4
on CPU Board
Continued!