Directed Electronics 554A Installation Manual page 30

Hide thumbs Also See for 554A:
Table of Contents

Advertisement

selectable in feature 3-6.
3-3 RUN TIME 12, 24, 60 MINUTES: Selects the time in minutes that the system will
operate the engine until the system "times out". This is the maximum operation period and
the system may be shut down using a shutdown at any time. Using the 998T Bitwriter
the run time can be programmed for any duration from 1-60 minutes.
3-4 PARKING LIGHTS FLASHING/CONSTANT: In the default setting, the unit will flash the
vehicle's parking lights (if connected) while remote started. The constant setting will turn the
parking lights on solid for the entire run duration.
3-5 CRANK TIME 0.6/0.8/1.0/1.2/1.4/1.6/1.8/2.0/4.0 SECONDS: If the unit is programmed for
no engine checking or voltage sense, the crank time must be set to the appropriate duration. The
default setting is 0.6 second. If a different crank time is desired, select feature 3-5 and select either
0.6 second by using the one-chirp setting or toggle through the higher settings by using the two-
chirp settings.
3-6 VOLTAGE CHECK HI/LOW: This feature only functions when programmed for voltage sense.
Some vehicles have many accessories, which are turned on when remote started. In these vehicles,
the variation of voltage between the engine off and the car running is very small and the remote
start unit may "think" the vehicle has not started. This can cause the remote start to shut-down after
the car has been started. If this happens program this feature to the LOW position.
3-7 AUXILIARY OUTPUT FACTORY DISARM/SPECIAL ACCESSORY: In the default setting the
LT. GREEN/BLACK, H2/2, wire sends a negative pulse that may be used to disarm the vehicle's
factory security system. If programmed for a special accessory, the wire can be used to energize a
relay to power up extra ignition wires in the vehicle. This wire must be used to energize circuits in
the vehicle that operate accessories, such as the radio or heater.
3-8 BLUE WIRE STATUS OUTPUT/FACTORY SECURITY RE-ARM OUTPUT: The blue
(H3/1) wire will supply a 200mA (-) output for the entire remote start run time. If programmed
for factory re-arm output, this wire will supply a momentary 200mA (-) pulse whenever the remote
start times out or is shut down with the transmitter. This can be used to re-arm many factory
security systems.
3-9 AUTOMATIC ANTI-GRIND ON/OFF: With the anti-grind ON (default) the ground-when-
armed output will be active during remote start operation. If accessories such as a voice module or
window module are added to the unit, it may be necessary to program this feature OFF.
30
®
©
2003
Directed Electronics, Inc.
,

Advertisement

Table of Contents
loading

Table of Contents