Toshiba RAV-HM301MUT-E Service Manual page 80

Hide thumbs Also See for RAV-HM301MUT-E:
Table of Contents

Advertisement

<RBC-AMTU3∗ ∗ ∗ ∗ ∗ >
1
Push the
+
least 4 seconds.
The unit No. displayed first is the address of the header indoor unit in group
control.
Then the fan and louver of the selected indoor unit move.
2
UNIT LOUVER
Each time the
one of the indoor unit number under group control is
displayed in turn. Then the fan and louver of the selected
indoor unit move.
3
Use the
button to select the CODE No. (DN code) of the
TEMP.
desired function.
4
Use the
button to select the desired SET DATA
associated with the selected function.
5
Push the
button. (The display changes from flashing to
steady.)
• To change the selected indoor unit, go back to step
• To change the selected function, go back to step
6
When the
button is pushed, the system returns to normal
off state.
NOTE :
For details on how to operate other remote controllers, refer to the remote controller manual.
+
buttons simultaneously and hold for at
button (left side of the button) is pushed,
2
.
3
.
– 80 –
10
SET DATA
00 01
SETTING
TEST
UNIT No.
1-1
R.C.
No.
TEMP .
ON / OFF
TIMER SET
FAN
TIME
SAVE
FILTER
RESET
TEST
SET
CL
SWING/FIX
UNIT LOUVER
5
4
3
1
2
6
CODE No.
MODE
VENT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rav-hm401mut-eRav-hm561mut-eRav-hm561mut-tr

Table of Contents