Problems After Initial Boot - HP ProLiant DL585 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL585:
Table of Contents

Advertisement

Problems after initial boot

After the server has passed POST, you might still encounter errors, such as an inability to load the operating system.
Use Table 33 to troubleshoot server installation problems that occur after the initial boot.
See the HP Servers Troubleshooting Guide for more information.
Table 33
Problems after initial boot
Problem
System cannot load ProLiant Essentials
Foundation Pack.
ProLiant Essentials fails during
installation.
Server cannot load operating system.
All manuals and user guides at all-guides.com
Possible reasons
ProLiant Essentials Foundation Pack
requirements not met.
CD-ROM drive is not properly seated.
Insufficient memory is available.
Existing software is causing conflict.
Error occurs during installation.
CMOS is not cleared.
Required operating system step was
missed.
Installation problem occurred.
Problem was encountered with the
hardware you have added to the system.
Possible solutions
Check the ProLiant Essentials Release
Notes provided in the ProLiant Essentials
Online Reference Information on the
ProLiant Essentials Foundation Pack.
Reseat CD-ROM drive.
A rare Insufficient Memory message
might display the first time ProLiant
Essentials is booted on certain
unconfigured systems. Cold boot the
machine with the ProLiant Essentials
Foundation Pack inserted in the CD-ROM
drive to correct the problem.
Run the System Erase Utility. Read the
Caution at the end of the table. See the
instructions in the HP Servers
Troubleshooting Guide.
Follow the error information provided. If
it is necessary to reinstall, run the System
Erase Utility. Read the Caution at the
end of the table. See the instructions in
the HP Servers Troubleshooting Guide.
Run the System Erase Utility. Read the
Caution at the end of the table. See the
instructions in the HP Servers
Troubleshooting Guide.
Follow these steps:
1
Note at which phase the operating
system failed.
2
Remove any loaded operating
system.
3
See the operating system
documentation.
4
Install the operating system again.
See the operating system documentation
and to the ProLiant Essentials Release
Notes on the ProLiant Essentials for
Servers CD.
Run RBSU and look at the OS Selection
menu.
See the documentation provided with the
hardware.
See the User Guide to identify correct
SCSI bus cabling configuration for the
unit.
Troubleshooting 80