Fisher & Paykel CLEANSMART 7 Series Installation Manual/User Manual page 9

Table of Contents

Advertisement

Water supply
Inlet hoses
Failure to adhere to the following instructions may result in a flood and
damage to property:
Straight
Elbow
(tap) end
(machine) end
Inlet hose ends
Only use the new hose set provided with your washer.
Water supply requirements:
If you have an uncontrolled water heating source (eg a wet back or solar heating
z
system) you should fit a tempering valve. This will ensure the hot water temperature
remains within safe limits. Contact your registered plumber to select and install the
tempering valve.
Your cold water should not exceed 35°C and your hot water should not exceed
z
65°C. Temperatures above these may cause the machine to fault or cause damage
to the machine.
Inlet water static pressure: Max. 1MPa (145psi) Min. 34KPa (5psi).
z
Inlet water flow rate at tap: Min. 8 litres/min.
z
This clothes washer should be plumbed into both a hot and cold water supply otherwise
some cycles may not function correctly. Your washer does not have an internal heater to
heat water.
INSTALLATION INSTRUCTIONS
1 Connect the straight ends of the inlet hoses to the taps
(there are washers fitted in both ends). Connect the
red connector hose to Hot, and the white connector
hose to Cold.
2 Connect the elbow ends of the inlet hoses to the
corresponding washer inlet valves. Inlet valves are
marked on the back of the washer. Ensure the Hot
valve is connected to the hot tap and the Cold valve is
connected to the cold tap.
H = Hot C = Cold
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cleansmart wl1068pCleansmart wl1068p1