3 Installation
Step 5
Insert the positive wire and negative wire into the corresponding insulation crust respectively. If there
has a click sound, it means it have been inserted properly.
Step 6
Tighten the sealing nuts of positive connector and negative connector to the corresponding insulation
crusts respectively.
Step 7
Insert the positive connector and negative connector into the ports marked with "+" and "-" in the
inverter respectively. If there has a click sound, it means it have been inserted properly, as shown in
Figure3-18 and Figure3-19.
Figure3-18 Connect with the positive pole of DC input
Figure3-19 Connect with the negative pole of DC input.
----End

3.5.3 AC Connection

When wiring, pay attention to distinguish the AC live wire, neutral wire and grounding wire.