I Error message list
Message
1
BRG INPUT FAIL*
1
TRIG SIGNAL FAIL*
2
SHM SIGNAL FAIL*
1
POSN INPUT FAIL*
CHECK SCANNER CONNECTION*
1
*
Push any key to cancel the error message and beep tone. Turn the power OFF, then check the external data
cable connection.
2
*
An electricity failure may occur, turn the power OFF, then consult your dealer or service man.
3
*
Push any key to cancel the error message and beep tone.
4
*
Turn the power OFF, then check the system cable connections.
• The Azimuth signal is interrupted. An alarm tone is emitted within
5 sec. and the display reverts to H UP mode in approx. 1 min.
• If the TRIGGER signal is interrupted for more than 15 sec., an alarm
tone is emitted.
• If the SHM signal is interrupted for more than 15 sec., an alarm tone is
emitted.
• If the position signal is interrupted for more than 15 sec., an alarm tone
is emitted.
4
• The system cable may not be connected properly.
ERROR MESSAGE
Condition
12
35