Perimeter Plexiglass; Access Panels; Installing Splashguard - Hussmann RI1 Installation And Operation Manual

Ri & si series island and multi-deck island cheese & deli
Hide thumbs Also See for RI1:
Table of Contents

Advertisement

P/N 0446551_A

PERIMETER PLEXIGLASS

When replacing a section of perimeter plexiglass,
first remove the applicable bolts holding it in
place, as illustrated below.
Typical
Bolt
Locations
Bolts feed
from Front
(Outside)

ACCESS PANELS

All electrical and drain access panels are clearly
labeled on the deck of the deli/cheese stand.
Access panels for the condensing unit in self-
contained models are located on the sides of the
stand, at one end. Panels are fitted for removal if
the condensing unit has to be taken out.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

INSTALLING SPLASHGUARD

After merchandisers have been leveled and re-
joined, and all drip piping, electrical and
refrigeration work has been completed, install the
splashguards. Splashguards may be sealed to the
floor using a vinyl cove base trim. The size of
trim needed will depend on how much the floor is
out of level. Note that the splashguard must be
removable to access components behind it.
1. Remove all dirt and wax, etc. from the area of
the splashguard to ensure a secure adhesion.
2. Apply a good contact cement to the trim,
allowing for proper dry-time.
3. Install trim to the splashguard so that it is
flush with floor. Do not seal trim to floor!
INSTALLER
It is the contractor's responsibility to
install case(s) in accordance with all local
building and health codes.
Island & Multi-deck Island
1-5

Advertisement

Table of Contents