PLEXIGLASS & ACRYLIC CARE
Improper cleaning not only accelerates the cleaning
cycle but also degrades the quality of this surface.
Normal daily buffing motions can generated static cling
attracting dust to the surface. Incorrect cleaning agents
or cleaning cloths can cause micro scratching of the
surface, causing the plastic to haze over time.
CLEANING
Hussmann recommends using a clean damp chamois, ,
or a paper towel marketed as dust and abrasive free
®
with 210
Plastic Cleaner and Polish available by

ELECTRICAL PRECAUTIONS

BEFORE SERVICING – Always disconnect
electrical power at the main disconnect when
servicing or replacing any electrical component
This includes (but not limited to) Fans, Heaters,
Thermostats, and Lights.
EVAPORATOR FANS
The evaporator fans are located at the center front of
these merchandisers directly beneath the display pans.
Should fans or blades need servicing, always replace fan
blades with the raised embossed side of the blade TOWARD
THE MOTOR.
COPPER COILS
The copper coils used in Hussmann merchandisers may
be repaired in the field. Materials are available from
local refrigeration wholesalers.
Hussmann recommends using #15 Sil-Fos for repairs.
calling Sumner Labs at 1-800-542-8656. Hard, rough
cloths or paper towels will scratch the acrylic and
should not be used.
ANTISTATIC COATINGS
®
The 210
has proven to be very effective in not only
cleaning and polishing the Plexiglass surface, but also
providing anti-static and anti-fog capabilities. This
product also seals pores and provides a protective
coating.

Maintenance

REPLACING FLUORESCENT LAMPS

Fluorescent lamps are furnished with a shatterproof
protective coating. The same type of lamp with protec-
tive coating must be used if replaced.
SHATTERPROOF COATING - SA 10645
U R
TIPS & TROUBLESHOOTING
Before calling for service, check the following:
1. Check electrical power supply to the equipment for
connection.
2. Check fixture loading. Overstocking case will affect
its proper operation.
When contacting the factory,
be sure to have the Case Model and Serial
Number handy. This information is on a plate
8
ENCAPSULITE
Complies with FDA USDA
& OSHA Regulations
1-800-395-9229
FOR PROMPT SERVICE
located on the case itself.