Cut & Plan Views; Location; Leveling; Joint Trim - Hussmann RGSSFP Installation And Operation Manual

Self service/food prep case
Hide thumbs Also See for RGSSFP:
Table of Contents

Advertisement

Rev. 0408
HUSSMANN CHINO PRODUCT CONTROL
The serial number and shipping date of all equipment has
been recorded in HUSSMANN's files for warranty and
replacement part purposes. All correspondence pertaining
to warranty or parts ordering must include the serial number
of each piece of equipment involved, in order to provide
the customer with the correct parts.
Cut & Plan views
End
Panel
8"
12"
19
/
"
1
2
Elec.
Access
12"
RGSSFP (S.C)
shown with Optional Refrigerated Rear Storage
Prep/Self-Service
CONDENSING
UNIT
DRAIN & ELEC.
MECHANICAL
STUB UP AREA
18" X 18"
1"
8"
8'-2" (4'-2", 6'-2")

LOCATION

The refrigerated merchandisers have been designed
for use only in air conditioned stores where temperature
and humidity are maintained at or below 75°F and 55%
relative humidity. DO NOT allow air conditioning, electric
fans, ovens, open doors or windows (etc.), to create air
currents around the merchandiser, as this will impair its
correct operation.
Product temperature should always be maintained at a
constant and proper temperature. This means that from the
time the product is received, through storage, preparation
and display, the temperature of the product must be
controlled to maximize life of the product.
Light
Ref. Dome
(Optional)
9
/
"
7
8
Coil
Condensing
Adj. Wire
Unit
Racks
S.C.
30"
8
/
"
1
4
48 "
REFRIG.
MECHANICAL
STUB UP AREA
none
CASE FRONT
8"
Plan View
UNCRATING THE STAND
Place the fixture as close to its permanent position as
possible . Remove the top of the crate. Detach the walls
from each other and remove from the skid. Unbolt the case
from the skid. The fixture can now be lifted off the crate
skid. Lift only at base of stand!
EXTERIOR LOADING
These models have not been structurally designed to
support excessive external loading. Do not walk on their
tops; This could cause serious personal injury and damage
to the fixture.
All cases were leveled and joined prior to shipment to ensure closest possible
fit when cases are joined in the field. To avoid removing concrete flooring,

LEvELING

IMPORTANT! It is imperative that cases be leveled from
front to back and side to side prior to joining. A level
case is necessary to insure proper operation.

JOINT TRIM

After the case has been leveled and joined, and
refrigeration, electrical, and waste piping work completed,
install the splash guards. Fasten along the top edge, or
center, with #10 X 3/8" sheet metal screws.
Do Not Seal Joint Trim To Floor!

WASTE OUTLET AND P-TRAP

The waste outlet is located off the center of the case on
one side allowing drip piping to be run lengthwise under
the fixture.
1"
A 1-1/" P-trap and thread adapter are supplied with each
fixture. The P-trap must be installed to prevent air leakage
and insect entrance into the fixture.
NOTE:
PvC-D Wv solvent cement is recommended.
Follow the manufacturer's instructions.

INSTALLING CONDENSATE DRAIN

Poorly or improperly installed condensate drains can
seriously interfere with the operation of this refrigerator, and
result in costly maintenance and product losses. Please
follow the recommendations listed below when installing
condensate drains to insure a proper installation:
1 . Never use pipe for condensate drains smaller than
the nominal diameter of the pipe or P-trap supplied
with the case.
 . When connecting condensate drains, the P-trap
must be used as par t of the condensate drain to
prevent air leakage or insect entrance. Store plumb-
3
AVOID REMOVING CONCRETE
begin lineup at highest point of store floor.

Plumbing

Advertisement

Table of Contents
loading

Table of Contents